Search arXivSearch

arXiv · 2606.19300

Confidence is Not Reliability: Rethinking MC Dropout in Brain Tumour Segmentation

Abstract

Glioma segmentation in multiparametric MRI is a critical component of treatment planning. A segmentation model that fails silently on treatment-critical sub-regions represents a patient safety risk that overlap-based metrics such as Dice scores cannot expose. We ask whether voxel-level uncertainty estimation via Monte Carlo (MC) Dropout can reliably identify segmentation errors in clinically critical sub-regions, and whether calibration failure modes are detectable from standard reporting metrics alone. In an empirical two-model case study on 126 BraTS21 patients, we evaluate a high-performance pretrained SegResNet and a locally trained UNet with residual units (UNet-Res). MC dropout preserved segmentation accuracy ($|Δ\text{Dice}|$ $<0.01$) while achieving strong uncertainty-error alignment (AUROC for entropy (H) $\approx$0.97), indicating uncertainty correctly ranks erroneous voxels above correct ones. Entropy-based patient stratification identified a high-uncertainty subgroup with substantially lower segmentation performance (median whole-tumour Dice $0.835$ vs. $0.925$), supporting uncertainty as a practical triage signal. However, global alignment can mask important region-specific differences. Despite similar AUROC, UNet-Res exhibited near-zero enhancing tumour entropy ($0.054$) and Expected Calibration Error (ECE) of $0.915$, with a Dice of only $0.714$, indicating severely miscalibrated confidence on the most clinically critical sub-region, a failure mode invisible to standard Dice and AUROC reporting. These findings demonstrate that strong uncertainty-error alignment is necessary but insufficient for clinical safety: sub-region-specific calibration assessment must accompany AUROC evaluation when selecting models for clinical deployment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Xin Ci Wong, Duygu Sarikaya, Kieran Zucker, Marc De Kamps, Nishant Ravikumar. 2026-06-17. Confidence is Not Reliability: Rethinking MC Dropout in Brain Tumour Segmentation. https://arxiv.org/abs/2606.19300

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Lifelong Learning of Video Diffusion Models From a Single Video Stream

Video diffusion models can enable embodied agents to anticipate plausible futures from the recent past, but they are typically trained offline on curated datasets--a mismatch with the agents' learning setup at deployment: online, from a single video stream that sequentially outputs one frame at a time. We bridge this training gap and demonstrate that training autoregressive video diffusion models from such a stream, resembling the experience of embodied agents, is not only possible but can also perform comparably to standard offline training given the same number of gradient steps. We find that this robustness to video stream autocorrelation and nonstationarity can be achieved using experience replay methods that retain a subset of the video stream. To support training and evaluation in this setting, we introduce five new datasets for streaming lifelong generative video modeling: Lifelong Bouncing Balls (O), Lifelong Bouncing Balls (C), Lifelong 3D Maze, Lifelong Drive, and Lifelong PLAICraft, each consisting of one million consecutive frames from environments of increasing complexity. Together, our datasets and experiments lay the groundwork for video generative models and world models that continuously learn from single-sensor video streams rather than fixed datasets.

cs.CV

Bayesian Fusion of Active Contour Models and ConvNet Priors for Standing Dead Tree Segmentation

Instance segmentation is a core computer vision task with great practical significance. Recent advances, driven by large-scale benchmark datasets, have yielded good general-purpose Convolutional Neural Network (CNN)-based methods. Natural Resource Monitoring (NRM) utilizes remote sensing imagery with generally known scale and containing multiple overlapping instances of the same class, wherein the object contours are jagged and highly irregular. This is in stark contrast with the regular man-made objects found in classic benchmark datasets. We address this problem and propose a novel instance segmentation method geared towards NRM imagery. We formulate the problem as Bayesian maximum a posteriori inference which, in learning the individual object contours, incorporates shape, location, and position priors from state-of-the-art CNN architectures, driving a simultaneous level-set evolution of multiple object contours. We employ loose coupling between the CNNs that supply the priors and the active contour process, allowing a drop-in replacement of new network architectures. Moreover, we introduce a novel prior for contour shape, namely, a class of Deep Shape Models based on architectures from Generative Adversarial Networks (GANs). These Deep Shape Models are in essence a non-linear generalization of the classic Eigenshape formulation. In experiments, we tackle the challenging, real-world problem of segmenting individual dead tree crowns and delineating precise contours. We compare our method to two leading general-purpose instance segmentation methods - Mask R-CNN and K-net - on color infrared aerial imagery. Results show our approach to significantly outperform both methods in terms of reconstruction quality of tree crown contours. Furthermore, use of the GAN-based deep shape model prior yields significant improvement of all results over the vanilla Eigenshape prior.

cs.CV

Sonicmesh: Enhancing 3D Human Mesh Reconstruction in Vision-Impaired Environments With Acoustic Signals

3D human mesh reconstruction (HMR) from RGB images often degrades under poor illumination, occlusion, and non-line-of-sight conditions. Acoustic sensing provides complementary spatial cues but suffers from low spatial resolution. We propose SonicMesh, which, to the best of our knowledge, is the first acoustic--visual framework for robust 3D human mesh reconstruction. SonicMesh first converts ultrasonic echoes into range--azimuth acoustic images through an Inverse Synthetic Aperture Radar (ISAR)-based imaging process. It then introduces a cross-dimensional anatomical registration module that maps modality-specific 2D joint features into a common canonical 3D human space. The registered anatomical representations are further integrated with acoustic and visual features through a two-stage fusion network for final mesh reconstruction. Experiments demonstrate that SonicMesh achieves accurate and robust 3D human reconstruction across normal, poor-light, occluded, and non-line-of-sight environments, consistently outperforming existing RGB-, radio-frequency (RF)-, and mmWave-based approaches under challenging sensing conditions.

cs.CV