Scene-based field validation of wearable light loggers

Abstract

Wearable light loggers are increasingly used to measure personal light exposure. However, there is no standardised method to test how well these devices perform in real-world settings. To address this, we developed a scene-based field validation framework combining wearable light loggers, laboratory-grade spectral reference instruments, and image-based scene characterisation to evaluate wearable performance in the field. We applied the validation framework to ActTrust2 and ActLumus light loggers using 433 natural, everyday scenes across two sites: Tübingen, Germany (n=210), and Izmir, Türkiye (n=223), spanning indoor and outdoor environments in daylight, artificial light and mixed scenarios, across wide range of photopic and melanopic equivalent daylight illuminances. Both light loggers exhibited high agreement with the reference instruments (R^2=0.988-0.990), but they systematically underestimated light exposure. The lighting condition, scene complexity, time of day, and study site contributed significantly to measurement bias. Resampling under specific lighting conditions indicated that bias ranged from -0.065 log units in daylight-only situations to -0.195 log units in artificial-only situations. This suggested that single-condition assessments with limited spectra or scene categories can underestimate or overestimate overall wearable performance. Bootstrap resampling demonstrated that performance estimates stabilised at approximately 100 scenes, indicating that a diverse sample of this size is sufficient for reliable field validation. Finally, cross-site validation showed consistent performance across two sites, supporting the framework's reproducibility. Overall, these findings establish our validation framework as an effective tool for guiding scene diversity and sampling design for ecologically valid field validation of wearable light loggers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Burcu Gemici, Niloufar Tabandeh, Cansu Ozkucukler, Johannes Zauner, Altug Didikoglu, Manuel Spitschan. 2026-06-16. Scene-based field validation of wearable light loggers. https://arxiv.org/abs/2606.20719

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det