A Reproducible Benchmark and Evidence-Retrieval Software Framework for Silicon Detector R&D Literature

Abstract

Silicon pixel detector R&D depends on a large and rapidly growing technical literature, including beam-test and irradiation studies, performance measurements, simulation, and design reports. Locating the supporting evidence passage for a measurement, operating condition, or design decision is therefore a computing and data-science challenge for detector-development workflows. General-purpose language models are insufficient unless grounded in traceable primary sources, particularly in a domain with specialised terminology, configuration-dependent measurements, and rapidly evolving experimental results. We address this with a reproducible, general-purpose framework for evidence-grounded retrieval over technical literature, using silicon pixel detector R&D as a demanding validation domain. The framework combines sparse lexical retrieval, dense semantic retrieval, and hybrid reciprocal-rank fusion, with an optional graph-guided exploration layer and grounded, abstention-aware response generation. The accompanying benchmark provides manually curated chunk-level evidence annotations, source-level diagnostics, semantic relevance checks, and negative-query abstention tests over two detector query sets. We evaluate six retrieval configurations across 378 source documents and 8,442 indexed chunks. Hybrid sparse-dense retrieval gives the strongest strict evidence recovery, achieving Hit@5 of 0.917 on the core benchmark and 0.951 on the curated extension benchmark, while graph-based methods are more effective for literature exploration and source discovery. Graph expansion is therefore best employed as a discovery layer over the hybrid retrieval backbone. The framework provides reusable software for traceable, 1 evidence-grounded knowledge access in silicon detector R&D and high-energy physics instrumentation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tianqi Gao, Ruobing Jiang, Dawei Fu, Qiang Li, Matthew Kenzie. 2026-07-02. A Reproducible Benchmark and Evidence-Retrieval Software Framework for Silicon Detector R&D Literature. https://arxiv.org/abs/2606.24725

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Kinematic Fitting of electromagnetic calorimeter data - an improved method

Kinematic fitting is widely used in particle physics experiments as a powerful tool to improve experimental resolutions, to suppress background and to provide selection criteria for the identification of specific reactions. Kinematic fitting methods, however, typically assume that the fitted quantities follow Gaussian distributions; an assumption which does not always hold. This is particularly true for energy measurements from electromagnetic calorimeters. This issue can largely be overcome by performing a transformation of the non-Gaussian variables into variables which follow a Gaussian distribution. The new adapted kinematic fitting procedure allows to better account for the non-Gaussian nature of the measured calorimeter energies, at the same time improving the accuracy and robustness of the kinematic fit. This leads to improved pull and confidence-level distributions of the kinematic fit as well as improved invariant mass distributions and signal-to-background ratios in the final event sample.

physics.ins-det

Radiation hardness characterization of SiPM sensors for Low Earth Orbit space missions

This work presents a comprehensive radiation hardness characterization of SiPM devices for space-based applications: FBK NUV-HD-MT and NUV-HD-LowCT (1$\times$1, 3$\times$3, and 6$\times$6~mm$^2$) and Hamamatsu S14160 MPPCs with equivalent active areas. Total Ionizing Dose (TID) tests were performed at the ESA/ESTEC Co-60 facility with a level of dose up to 20~krad in silicon, while displacement damage effects were evaluated using 100~MeV protons with a fluence up to $1.12\times10^{11}$~p/cm$^2$ at the Paul Scherrer Institute. Radiation damage in SiPMs manifests through two main mechanisms: ionizing energy loss and non-ionizing energy loss (NIEL), which increases dark current and dark count rate. In this work, breakdown voltage, dark current, and quenching resistance were systematically measured as functions of accumulated dose and fluence. Gain and dark count rates were indirectly measured from the characterized electrical parameters. Both technologies exhibit remarkable stability of most of the functional parameters across all dose levels, while dark current shows predictable increases significantly more pronounced under proton irradiation due to displacement damage. Based on these results, both FBK and Hamamatsu devices are confirmed suitable for Low Earth Orbit (LEO) mission environment.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det