Abstract

This paper designs and develops a miniaturized photoacoustic spectroscopy gas probe with acoustic pressure enhancement for in-situ detection in oil-immersed power equipment. The probe adopts a single-cavity single-fiber structure, integrating the photoacoustic cell and the Fabry-Pérot optical sensing cavity within a ceramic ferrule with an outer diameter of only 800 um. Through the electro-mechanical-acoustic equivalent model analysis of the semi-open photoacoustic cell, the enhancement mechanism is revealed that reducing the radius of the photoacoustic cell can form a flat region in the acoustic pressure response. The CrAgAu composite metal diaphragm is fabricated by electron-beam evaporation, and the gas vents are precisely machined by focused-ion-beam etching, successfully realizing the preparation of the sensor prototype. Experimental results demonstrate that the sensor exhibits a flat acoustic response in the frequency range of 2800-10000 Hz with a sensitivity of -15 dB re 1 mV/Pa. Using acetylene as the target gas, the detection limit reaches 71.4 ppb (with an integration time of 130 s) at the optimal operating frequency of 3275 Hz, and the linearity exceeds 0.998. In-oil tests verify its stable detection capability in oil-phase environments, providing a miniaturized, high-sensitivity all-optical technical solution for in-situ monitoring of dissolved gases in transformer oil.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yi Zhong, Yuxiang Zhao, Ping Lu. 2026-07-03. Miniaturized Photoacoustic Spectroscopy Gas Probe for In-Situ Detection in Oil. https://arxiv.org/abs/2607.03053

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Development of an Extensible Unified Control System Using the STARS Framework and Common Commands for Detector Control

A zooming optical system comprising two Fresnel zone plates (FZPs) was developed and installed at the AR-NE1A beamline of the Photon Factory, High Energy Accelerator Research Organization (KEK), Japan. To ensure reliable and versatile operation, we implemented a dedicated control architecture based on the Simple Transmission and Retrieval System (STARS) framework and the newly proposed STARS Common Commands for Detector Control (CCDC)---a data-acquisition (DAQ) state model and command set designed specifically for detector control. The system serves both as a practical control system for the zooming optics and as a demonstration of modular extensibility using STARS and detector interoperability through CCDC. The system has been commissioned, and its performance has been verified at the AR-NE1A beamline. The architecture enables flexible configuration of optical components and provides a unified interface for both routine operation and advanced experimental protocols.

physics.ins-det

Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors

Experimental TCAD calibration is essential for predictive technology modeling of emerging oxide semiconductor transistors. However, it remains time-consuming and expert dependent because of model ambiguity. Multiple physical models and parameter sets can reproduce the same measured transfer characteristics, while local fitting alone cannot uniquely identify the underlying device physics. We present the first demonstration of an agentic TCAD calibration workflow for a fabricated bottom-gate In--W--O (BG-IWO) transistor. Starting from the measured transfer curve and device information, the workflow uses measurement--TCAD residuals and local sensitivity tests to select bounded parameter corrections or evaluate additional physical models, and accept only updates that improve device metrics. The LLM agent orchestrates the workflow, while Sentaurus governs the device physics. For the 2\%-W reference device, five agent-suggested updates yield a fixed calibrated model, reducing the multi-metric device objective $J$ by 14.3$\times$. Maximum $V_{\mathrm{th}}$/$I_{\mathrm{on}}$ errors are 36.1~mV/0.022 decade for varying-drain-bias tests and 46.2~mV/0.062 decade for varying-channel-length tests, demonstrating model transferability across bias and geometry rather than a local parameter fit. W-composition tests provide process-sensitive insight. This agentic workflow provides a faster route to model development for emerging device technologies.

physics.ins-det

Birefringence of AlGaAs/GaAs Coatings under Above-Band-Gap Illumination, GR Noise and Photo-Optic Transfer Function

AlGaAs/GaAs coatings are being considered as coating candidates for gravitational-wave detectors. In this paper we investigate the birefringence properties of this crystalline semiconductor material by modulating the optical illumination on the mirror coating and monitoring the induced birefringence. While the measured low-frequency birefringence values align with previous studies, we observed a frequency-dependent behavior in the illumination-to-birefringence coupling, characterized by a pole increasing with illumination intensity and a gain at zero frequency (DC gain) decreasing with illumination intensity. We developed a generic theoretical model based on a master equation to characterize the measurement results by considering photon-induced electric fields and electro-optic effects. This model can fit the frequency and intensity dependencies of the induced birefringence. Additionally, this model predicts a generation-recombination noise (GR noise) will be observable in the coating birefringence. While the presented measurement cannot predict the exact level of GR noise, for the frequency band and spot sizes relevant for gravitational-wave detectors we expect GR noise to be white below the pole frequency, scale with power the same way laser shot noise does, and for fixed power be independent of spot size.

physics.ins-det