Search arXivSearch

arXiv · 2607.09831

Slide-Level Active Learning Reduces Annotation Burden in H&E images

Abstract

Deep learning-based segmentation of histopathology whole-slide images (WSIs) requires large amounts of pixel-level annotations, which are costly and time-consuming to obtain. Active learning (AL) has been proposed to reduce this effort, but existing methods exhibit three key limitations. Uncertainty estimation is unreliable on partially annotated WSIs, patch-level acquisition is inconsistent with slide-level annotation workflows, and class imbalance in multi-class settings is not explicitly addressed. To address these challenges, we propose SHAL (Slide-level Hybrid Active Learning), a patient-level AL framework for annotation-efficient multi-class histopathology segmentation. SHAL integrates three complementary components: a foreground-aware strategy that suppresses bias from unlabeled background regions, a stage-adaptive mechanism that hybridizes predictive entropy and epistemic uncertainty across learning stages, and a class-aware strategy that prioritizes diagnostically relevant tissue classes. SHAL is evaluated on the TCGA colorectal cancer dataset. It achieves the highest Macro Dice at the full annotation budget (0.846) and reaches Dice greater than or equal to 0.80 using only 26 percent of the budget (50 of 190 slides), whereas competing methods reach this threshold only at 37 percent (70 slides). Across five independent external cohorts, SHAL attains the highest mean external Macro Dice (0.815) and the smallest internal-to-external generalization gap among all methods (0.025 at Round 3 and 0.026 at the full budget). The results indicate that patient-level hybrid uncertainty acquisition reduces annotation cost without sacrificing cross-domain generalization in computational pathology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mahsa Vali, Zhilong Weng, Noémie Moreaua, Yuri Tolkach, Katarzyna Bozek. 2026-07-10. Slide-Level Active Learning Reduces Annotation Burden in H&E images. https://arxiv.org/abs/2607.09831

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV

Recasting the Destroy Step of Large Neighborhood Search as Dense Segmentation

Large neighborhood search improves an incumbent by releasing selected variables and repairing the resulting subproblem under a time limit. FOVEA casts variable selection as dense semantic segmentation on a fixed $128\times128$ canvas. A small U-Net reads twelve semantic channels and predicts cell scores, which are decoded into a variable set subject to a fixed variable budget. Family-specific layouts connect the search state to the canvas, while one set of network weights serves four problem families. The FP32 network input occupies $786$\,kB across instance sizes. Our analysis bounds constraint coupling for spatially coherent regions, gives a rank certificate for rounds with zero possible improvement, and bounds the coupling advantage attainable on an expander family. On the tested families and hardware, FOVEA trails the strongest graph encoder at $10^{4}$ variables and overtakes it near $1.5\times10^{4}$; the cost model provides an approximate crossover estimate. At larger sizes, where the graph-encoder baselines exceed device memory, FOVEA reduces the primal integral by $12$ to $16\%$ relative to the best runnable baselines. On the expander family, FOVEA performs comparably to random selection, with a coupling advantage close to one.

eess.IV