Search arXivSearch

arXiv · 2607.19585

Characterising the response of an International LOFAR Station

Abstract

Phased-array radio interferometers with fixed antennas are a highly scalable design which can achieve a large gain. However they are complex systems and challenging to calibrate. Here we examine the response of an International LOFAR Station, the high-band antennas of the Irish LOFAR station. In modelling our measured responses, we account for projection effects, the frequency-dependence of the aperture efficiency and pulsar spectra, as well as sky and instrumental noise contributions. We perform long-track observations of 11 bright pulsars as they move across the sky, apply RFI mitigation and determine the signal-to-noise ratio response as a function of time, elevation and azimuth. We use the DreamBeam software to model the beam response of the station to compare with what is observed. The sensitivity map so obtained was validated using observations of PSR B0329+54 on the Swedish LOFAR station. As expected, the sensitivity is higher near the zenith. However, an asymmetry with respect to the zenith point is detected. Characterising the instrumental response in azimuth reveals a better performance as the targets rise, as compared to when they set. This trend is seen for all pulsars and is consistent with other International Stations. The magnitude of the effect can exceed 20%. We consider variations in the beam model and noise level, both frequency- and time- dependent, to try to account for this. A possible explanation for the hysteresis-like response in elevation could be an imbalanced signal weighting of the polarisation components. This work addresses the importance of accurate beam modelling and noise evaluation for the LOFAR 2.0 system upgrade as well as being relevant to the under-construction SKA-Low facility.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Letizia Vincetti, Sai C. Susarla, Owen A. Johnson, Evan F. Keane, David J. McKenna, Tobia D. Carozzi, Gavin Ramsay, Oisin Creaner, Peter T. Gallagher, Joe McCauley. 2026-07-21. Characterising the response of an International LOFAR Station. https://doi.org/10.33232/001c.165435

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM