Search arXivSearch

arXiv · 2607.24265

Spatial resolution for gamma ray interactions in stacks of monolithic silicon sensors

Abstract

We are developing a new implementation of Compton imaging for nuclear medicine using a large volume of stacked monolithic silicon sensors. In this work we investigate how the spatial resolution is impacted by the pixel size, an important input to the design of the sensors. In general CMOS design is less challenging with larger pixels leaving more space for analog and digital electronics. On the other hand, spatial resolution is one of the key parameters that will impact the performance of the Compton imaging system. It is also important to consider the range of the recoil electron produced in Compton or photoelectric interactions, which impacts how accurately the interaction point can be estimated. The achievable resolution was evaluated with two interaction position reconstruction algorithms: one based on a Gaussian fit of the detected charge and a second based on the characteristic energy deposition along the electron track, with the former performing better at lower energies. Monte Carlo simulations were performed for 140 keV and 511 keV sources embedded in a water phantom, with pixel pitches ranging from 25 $μm$ to 250 $μm$. Energy-averaged in-plane resolution degraded from 8 $μm$ to 94 $μm$ as pixel size increased. The out-of-plane resolution was 216 $μm$ at low energies, limited by sensor thickness, and improved to 155 $μm$ at higher energies. The results suggest that pixel sizes in the order of 100 $μm$ can achieve spatial resolutions on the order of tens of micrometers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Luca Terenzi, Sara Garbolino, Elias Rieger, Mats Persson, Moa Yveborg Tamm, Manuel Da Rocha Rolo, Lucio Pancheri, Mats Danielsson. 2026-07-27. Spatial resolution for gamma ray interactions in stacks of monolithic silicon sensors. https://arxiv.org/abs/2607.24265

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det