108 ps coincidence time resolution through optimized scintillators, photodetectors, readout electronics, and DOI-based timing correction in orthogonally stacked detector configurations

Abstract

Objective. Existing commercial time-of-flight positron emission tomography (TOF-PET) systems yield a coincidence time resolution (CTR) of ~200 ps or less full width at half maximum (FWHM). Recently, there has been a challenge to achieve a CTR of 100 ps FWHM at the system level. However, current silicon photomultipliers (SiPMs) and 20-mm-thick scintillators in conventional single-ended readout scheme is difficult to achieve 100 ps CTR; the photon transport time spread (PTS) within the scintillator crystal is a major barrier. Differences in the interaction position result in variations in PTS on the order of several tens of ps, thereby degrading the CTR. A shorter scintillator can improve CTR; however, this can degrade detection efficiency. Approach. To overcome this trade-off between the CTR and detection efficiency, we previously proposed xDetector, an orthogonally stacked configuration along the longitudinal axis of scintillator crystals. We investigated the CTR potential of the xDetector by improving the scintillator, photodetector, and readout electronics, and by applying CTR correction based on a three-dimensional interaction within the scintillator. Main results. Based on error propagation, the CTR of the paired xDetector was calculated as 113.5 $\pm$ 2.7 ps FWHM. Furthermore, the CTR of the xDetector was measured at four positions along the longitudinal axis by manually sliding the xDetector, and the corrected achieved CTR was 108.6 $\pm$ 1.9 ps FWHM. Moreover, compared with the conventional single detector using a 20.0 mm scintillator, CTR improved by an average of 10.3%. Significance. The xDetector offers potential as a PET detector concept to achieve a CTR of 100 ps FWHM. Such timing performance is expected to improve TOF-PET image quality and quantitative accuracy, contributing to more reliable disease detection and diagnosis than current PET detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Arisa Sanzen, Yuya Onishi, Takahiro Moriya, Tomohide Omura, Ryosuke Ota. 2026-08-07. 108 ps coincidence time resolution through optimized scintillators, photodetectors, readout electronics, and DOI-based timing correction in orthogonally stacked detector configurations. https://arxiv.org/abs/2608.06746

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Voxel-Matching NORDIC: Non-local patch formation by time-series similarity increases tSNR in high-resolution BOLD fMRI

Submillimeter functional magnetic resonance imaging (fMRI) based on blood-oxygenation-level-dependent (BOLD) signal enables the study of brain function at the submillimeter level, uncovering insights into fine-scale organisations like cortical layers and columns. However, its inherently low contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) often limit its reliability and applicability. Noise Reduction with Distribution Corrected Principal Components Analysis (NORDIC PCA) is a locally low-rank denoising algorithm that reduces thermal noise levels in BOLD fMRI in a local patch manner. However, local patches often contain a mixture of signals from multiple tissues that negatively affects the low-rank structure of the patches, which limits the denoising capabilities of the algorithm. We propose an alternative approach for patch formation by gathering similar non-local voxels, dubbed voxel-matching (VM) NORDIC. The results on submillimeter-resolution BOLD fMRI data indicate that VM-NORDIC effectively promotes the low rank of the patches by boosting signal redundancy, allowing for more efficient noise attenuation. Moreover, the method barely affects spatial smoothness due to the non-local voxel selection based on time-series similarity. In particular, VM-NORDIC outperforms standard NORDIC with default local patching (Standard-NORDIC) in terms of temporal SNR (tSNR) (~9-90% larger than Standard-NORDIC; ~23-250% larger than the original) and spatial smoothness estimates (~20% of the smoothness induced by Standard-NORDIC). These improvements are fundamental to improving the validity and precision of fMRI studies at submillimeter resolutions.

physics.med-ph

Computed Tomography Reconstruction Algorithm Using Markov Random Field Model

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small computational cost. Under low-dose or sparse-view conditions, however, FBP often amplifies noise, severely degrading the reconstructed images. In this study, we evaluated the performance of a Bayesian CT reconstruction algorithm based on the Markov random field model under such adverse conditions. Through simulations, we demonstrated that the proposed algorithm shows higher reconstruction performance than FBP under both low-dose and sparse-view conditions. The hyperparameters are estimated by minimizing the Bayesian free energy, enabling adaptive reconstruction that reflects the noise characteristics of the observed projection data. These results suggest that the proposed algorithm can broaden the applicability of CT to dose-sensitive applications and time-constrained measurements, where only limited observed projection data are available.

physics.med-ph

Charge Collection Efficiency in Air-Vented Plane-Parallel Ionisation Chambers at Ultra-High Dose Rates: A Self-Consistent Garfield++ Monte Carlo Model Including Space-Charge Effects and Ion Recombination

Ultra-high dose rate (UHDR) irradiation used in FLASH radiotherapy can lead to significant reductions in charge collection efficiency (CCE) in plane-parallel ionisation chambers (PPICs) due to enhanced ion recombination, while the high charge densities involved can also induce strong space-charge-induced electric-field distortions. To investigate these coupled effects, we extended the Garfield++ Monte Carlo particle-transport framework by implementing ion--ion recombination and self-consistent space-charge electric field calculations. The developed Monte Carlo model couples particle transport, electron attachment, recombination processes, and dynamic electric-field distortions. The implementation was validated against analytical and numerical models from the literature. Excellent agreement was obtained for the free electron fraction (FEF), CCE, induced current, and electric field evolution under UHDR conditions. The simulations show that space charge can locally increase the electric field by more than a factor of four or reduce it to nearly zero in some regions of the chamber. The results further suggest that the reduction of the CCE under UHDR conditions is mainly driven by the decrease of the FEF caused by electric-field-dependent electron attachment. This finding indicates that the complex problem of recombination under UHDR conditions may be largely governed by the evolution of the FEF, opening promising perspectives for the development of improved analytical models and real-time correction methods for ionisation chamber dosimetry under UHDR irradiation conditions. This work provides a flexible and self-consistent Monte Carlo framework for investigating recombination phenomena and improving dosimetry models for FLASH radiotherapy.

physics.med-ph