Search arXivSearch

arXiv · 2608.10020

MD2G-Cast: Relay-Coordinated Multicast for Scalable Volumetric Streaming over MoQ

Abstract

Volumetric streaming remains difficult to scale because receivers with overlapping fields of view are often served independently, causing repeated transmission of shared content. We present MD2G-Cast, a relay-coordinated multicast framework over Media over QUIC with an application-aware control layer for scalable multi-user volumetric delivery. MD2G-Cast jointly uses viewing overlap, receiver capability, and bandwidth conditions to form reusable multicast groups, share common Base content, and selectively admit Enhanced delivery. We formulate grouping and Enhanced admission as a sequential control problem, realize it with Proximal Policy Optimization (PPO), and train a compact relay model with teacher guidance for Enhanced admission. We implement MD2G-Cast with real MoQ processes and evaluate it with real access and 6DoF viewing traces for up to 100 users. At 20 and 100 users, MD2G-Cast keeps the receiver-side $P_{99}$ delivery interval below 40 ms across all seven access profiles, while Rolling reaches the 500 ms reporting cap in most cases. Across the evaluated user scales, MD2G-Cast achieves the highest or tied-highest mean system utility under homogeneous access and the highest mean utility under heterogeneous access, while reducing aggregate link load by about 27% relative to Clustering at 100 users. A matched relay-control ablation separates the control structure from its optimizer, showing that random feasible actions reduce utility while deterministic control remains competitive with PPO. Together, the results support relay coordination and selective Enhanced admission, rather than a particular policy optimizer, as the central design contribution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ruonan Chai, Yisu Wang, Zili Meng, Dirk Kutscher. 2026-08-09. MD2G-Cast: Relay-Coordinated Multicast for Scalable Volumetric Streaming over MoQ. https://arxiv.org/abs/2608.10020

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

LaminoDiff: Generative Computed Laminography via Near-Isotropic Spectral Supervision and Anisotropic Geometry

Computed Laminography (CL) is widely used for nondestructive inspection of extended planar objects, but its restricted angular coverage produces an anisotropic point spread function, missing-cone spectral incompleteness, and severe aliasing with interlayer leakage. This paper presents LaminoDiff, a physics-constrained diffusion framework for CL reconstruction. During training, a CT-derived near-isotropic supervision target is reconstructed from full-angle Computed Tomography (CT) projections physically degraded to match CL detector noise and focal-spot blur while retaining full angular coverage; it is withheld from inference. At inference, the reverse process uses only the CL observation. An Anisotropic Representation (AR) constructs depth-aware channels from three adjacent slices: a neighbor average, a center-neighbor residual, and the retained current slice, followed by directional in-plane feature extraction. Experiments on simulated and real multilayer printed circuit board data, including ball grid array and high-frequency stub samples, show that LaminoDiff improves artifact suppression, edge preservation, and depth stratification over analytic Feldkamp--Davis--Kress and representative learning-based baselines.

eess.IV

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV