TARDIS Lab: infrastructure for characterization and assembly of highly granular silicon calorimeter modules for LUXE and future Higgs Factories

Abstract

The TARDIS Lab has been established at IFIC (CSIC-UV) to develop infrastructure and expertise in high-granularity silicon calorimetry. The laboratory provides an ISO7 clean-room environment and dedicated instrumentation for silicon sensor characterization and ultra-thin calorimeter module assembly. It supports developments of silicon-based high-granularity calorimetry concepts pursued within CERN DRD Calo (DRD6) and the FCAL Collaboration. These developments serve not only as technological prototypes of the electromagnetic calorimeters and luminometers at future Higgs-factory proposals (FCC-ee, Linear Collider Facility at CERN, International Linear Collider, etc.) but are also essential for the strong-field QED program of the LUXE experiment. We describe the laboratory infrastructure, assembly workflows and DESY test-beam validation of fully assembled calorimeter modules. The assembled ECALp modules have an average thickness of approximately 760~$μ$m, while laboratory tests of 4352 channels identified connectivity problems in only 0.5\% of them. For the two SiWECAL modules assembled in 2025, connectivity problems were observed at the level of approximately $10^{-3}$ of the instrumented pads, with no mechanical failures or sensor delamination after transport and beam operation. We also present ongoing infrastructure upgrades and production milestones for 2026-2027.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Melissa Almanza-Soto, César Blanch, Shan Huang, Adrián Irles, Carlos Orero. 2026-08-17. TARDIS Lab: infrastructure for characterization and assembly of highly granular silicon calorimeter modules for LUXE and future Higgs Factories. https://doi.org/10.1140/epjp%2Fs13360-026-08124-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det