Search arXivSearch

arXiv · 2608.18970

On-chip Bragg peak extraction from MHz frame rate X-ray detectors using a cellular automaton architecture

Abstract

High-frame rate pixel detectors can produce data volumes that exceed available off-chip bandwidth, yet in many applications only a sparse subset of each frame carries relevant information. Spatially localized events, including diffraction peaks in crystallography, particle hits in tracking detectors, fluorescence spots in biological imaging, and other applications, all require that clusters of above-threshold pixels be identified and extracted from an otherwise featureless background. Conventionally this is performed in software algorithms such as connected-component labeling on full frames, but at MHz frame rates the resulting throughput becomes prohibitive. We present a lightweight hardware architecture that performs peak localization and patch extraction directly in the sensor silicon, transmitting only small pixel patches rather than complete frames. FPGA-based testing on an AMD Alveo V80 validated the synthesizability and timing closure of the peak-finding module in real hardware. The design replaces global connected-component labeling with a cellular automaton that uses purely local, fixed-iteration neighborhood operations, eliminating the label storage and equivalence-resolution logic that make conventional approaches impractical on-chip. We validate the architecture on X-ray Bragg peak detection for far-field high-energy diffraction microscopy and show that every peak found by a software reference is recovered, with equivalent downstream reconstructions. The architecture sustains several-hundred-kHz frame rates in 130nm CMOS and exceeds 1MHz in 28nm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. Fowler, S. Strempfer, D. Beniwal, M. Hammer, H. Shi, S. Gnanasekaran, N. Contini, T. Guruswamy, Y. Chen, L. Rota, D. Doering, A. Dragone, T. Zhou, M. Cherukara, K. Yoshii, A. Miceli. 2026-08-19. On-chip Bragg peak extraction from MHz frame rate X-ray detectors using a cellular automaton architecture. https://arxiv.org/abs/2608.18970

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det