Search arXivSearch

arXiv · 2608.19051

The Radioactive Background of the JUNO Calibration System

Abstract

The Jiangmen Underground Neutrino Observatory (JUNO) experiment is a reactor antineutrino detector employing 20 kton of ultra-pure liquid scintillator to determine the neutrino mass ordering and to precisely measure oscillation parameters. The total singles background rate from radioactivity is required to be below 10 Hz in the energy range of 0.7-12 MeV within the fiducial volume for reactor neutrino analysis. The calibration system is designed to characterize the detector energy and position responses, while several of its components are located close to the target and may contribute to the background budget. Therefore, extensive material screening and selection are required to construct a low-background calibration system and to ensure that its contribution remains within the design requirements. In this work, a comprehensive study of the radioactive background induced by the calibration system is presented, including material radioactivity measurements using high-purity germanium detectors and neutron activation analysis techniques, detailed Monte Carlo simulations to evaluate the background, and comparisons with in-situ detector data to validate the predictions. In this data analysis, dedicated spatial selection methods are developed to isolate calibration-related contributions and to suppress the liquid scintillator background. The total radioactivity contribution from the calibration system is estimated to be less than 76 mHz, which satisfies the requirement of 200 mHz (2% of the total background budget). The results from in-situ data are found to be consistent with the expectations based on material assay and simulation within uncertainties. These results demonstrate that the calibration-induced background is well understood, in agreement between data and simulation, and negligible for reactor antineutrino measurements in JUNO.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rui Li, Youhui Yun, Zhangming Chen, Junting Huang, Jiaqi Hui, Haojing Lai, Jianglai Liu, Yankai Liu, Yue Meng, Akira Takenaka, Ziqian Xiang, Feiyang Zhang, Ping Zhang, Qingmin Zhang, Tao Zhang, Yuanyuan Zhang. 2026-08-19. The Radioactive Background of the JUNO Calibration System. https://arxiv.org/abs/2608.19051

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det