Search arXivSearch

arXiv · 2608.21103

Symmetry Constrained Quantum Error Mitigation for the Schwinger Model

Abstract

Quantum error mitigation (QEM) is at the very heart of near-term quantum simulations and lattice gauge theories are no exceptions, rather their physical symmetries provide natural consistency checks on noise quantum states. In this work, we exploit the parity and fermion-number symmetries of a gauge theory, the (1+1)-dimensional Schwinger model, under depolarising noise and investigate symmetry verification under digital quantum simulation. We investigate two set-ups - symmetry- sector post-selection in adiabatic state preparation followed by real-time measurements of the chiral condensate and symmetry verification within a variational quantum eigensolver (VQE). In the first case, post-selection reduces the bias in the chiral condensate consistently removing up to 60% of the quantum noise induced error in our system. Motivated by the observed regularity of the residual bias (in the low-noise regime), we further introduce a global-noise calibration obtained from classically accessible smaller lattices and implemented on larger lattices recovering noiseless chiral condensate values within statistical uncertainty. However, in VQE, symmetry verification does not seem to generally improve the optimised parameters or the fidelity of the prepared states, although it reduces the bias in the estimated ground-state energy. This demonstates that improving a noisy cost-function estimator in variational algorithms does not necessarily improve the outcome of the algorithm. Our results show the strength of symmetry verification in different approaches while establishing that its usefulness critically depends on where it is applied in the computational workflow, and provide practical guidance for symmetry-assisted quantum error mitigation in quantum simulations of lattice gauge theories.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alexander Tomlinson, Graham Van Goffrier, Bipasha Chakraborty, Zhenyu Cai. 2026-08-21. Symmetry Constrained Quantum Error Mitigation for the Schwinger Model. https://arxiv.org/abs/2608.21103

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Iteratively decoded magic state distillation

We present numerical simulation results for the 7-to-1 and 15-to-1 state distillation circuits, constructed using transversal CNOTs acting on multiple surface code patches. The distillation circuits are decoded iteratively using the method outlined in [arXiv:2407.20976]. We show that, with a re-configurable qubit architecture, we can perform fast magic state distillation in $\sim\mathcal{O}(1)$ code cycles. We confirm that both circuits suppress an injected input logical error rate $p$ to $\mathcal{O}(p^3)$ in the presence of additional circuit-level noise. This is done with two types of stabiliser proxies, distilling logical $|-\rangle$ and $|Y\rangle$ states, the latter is the intended state of the 7-to-1 circuit while a stabiliser-proxy for the 15-to-1 circuit. We then also provide numerical evidences for actual $|T\rangle$ state distillation using the 15-to-1 circuit with a faulty-$T$ measurement, leveraging recent near-Clifford simulation tools. Finally, we outline how ZX-calculus and Pauli webs can be used to benchmark stabiliser proxies for these distillation circuits.

quant-ph

Enhanced measurements on quantum computers via the simultaneous probing of non-commuting Pauli operators

Measuring the state of quantum computers is a highly non-trivial task, with implications for virtually all quantum algorithms. A promising avenue is multi-copy schemes, where identical copies of a quantum state are measured jointly so that all Pauli operators within the considered observable can be simultaneously assessed. Here, we present a first implementation of such a two-copy scheme in a measurement protocol. Based on Bayesian statistics, it accurately estimates not only the average of the desired observable but also the error en route. This enables an adaptive shot-allocation algorithm that preferentially samples the most uncertain Pauli terms. In regimes with many non-commuting Pauli operators, this ``double'' scheme can outperform the state-of-the-art measurement protocol in minimizing total shots for a given precision. We also numerically confirm the finding in previous theoretical works that the two-copy scheme incurs an overhead due to the square-root relationship between the variance of measured quantities and the number of measurement shots.

quant-ph

Thermodynamics of a phaseonium-driven optomechanical Otto engine

We study an optomechanical Otto engine whose working medium is a single-mode cavity driven by beams of coherently prepared three-level phaseonium atoms. The atoms are not thermal reservoirs in the Gibbs sense; rather, their populations and ground-state coherence set the detailed-balance ratio of the cavity collision map, so that the field relaxes to a Gibbs state at an operational apparent temperature. We combine the finite-time collision-model dynamics with radiation-pressure work extraction and compare three reservoir preparations: a thermal reference at the same apparent temperatures, an incoherent atomic beam with the same populations, and the coherent phaseonium beam. We show that the phaseonium isochore charges the cavity passively: the cavity ergotropy and energy-basis coherence remain zero up to numerical precision, while the state converges to the Gibbs fixed point selected by the apparent detailed balance. We further estimate lower bounds on the cost of preparing the atomic populations and coherence, showing that the relevant advantage of phaseonium is a resource-preparation tradeoff rather than a cost-free enhancement over a thermal bath at the same temperature. Finally, we assess the finite-time performance of a two-cavity cascade with additive mechanical work accounting. Over the investigated coherence-phase range, the cascade produces approximately $47\%$--$52\%$ more power than the single-cavity engine while requiring only $65\%$--$68\%$ of the hot and cold phaseonium atoms needed by two independent engines, resulting in a $9\%$--$15\%$ enhancement of power per injected atom over a complete cycle.

quant-ph