Search arXivSearch

arXiv · 2608.21820

On the Fundamental Limits of Single-snapshot Compressive Ultrasound Imaging Using Random Aberrative Masks

Abstract

Compressive sensing emerges as a paradigm shift to realize real-time volumetric ultrasound imaging using a single element transducer equipped with an aberrative mask. Such a coded aperture encodes each scatterer in the FoV as a specific echo signal, compressing each volumetric into a time sequence that are reconstructed into image via computational methods. Compressive imaging (CI) can greatly reduce the data rate and simplify the electronics. Despite this potential, the practical performance of single-snapshot CI remains unclear, especially how it is influenced by mask design, imaging task complexity, and reconstruction strategy. For this, we separate the information budget provided by the mask from the algorithm-dependent extraction of the encoded information. First, the spatial impulse responses of random masks with different pixel sizes and time-delay ranges were calibrated, and the entropy-based effective rank of their similarity matrix was used to quantify the available encoding capacity. Masks with pixel size of approx. half wavelength and a time-delay range of two carrier periods provided higher encoding capacities, reaching up to 1.1% of the total sampled voxels. Algorithm-dependent information extraction was further evaluated for both ULM-motivated particle localization and B-mode imaging. For particle localization, L1-norm regularized least-squares method reconstructed particles corresponding to approx. 10% of the available encoding capacity, outperforming the matched filter. A transition from successful to failed reconstruction was observed when the number of particles exceeded this value, revealing the upper limit of the present CI systems using random masks. For B-mode imaging, LSQR achieved the highest SSIM among the evaluated methods, of up to 0.12, although the encoding capacity of the current random masks remained insufficient for high-fidelity reconstruction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zehua Dou, Yaokuan Zhang, Jialong Zhang, Cherif Othmani, Lars Büttner, Jürgen W. Czarske. 2026-08-22. On the Fundamental Limits of Single-snapshot Compressive Ultrasound Imaging Using Random Aberrative Masks. https://arxiv.org/abs/2608.21820

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Measuring vacancy-type defect density in monolayer semiconductors

Two-dimensional (2D) materials have attracted wide-spread interest due to their unique and tunable properties. Their optoelectronic, mechanical, and thermal properties are greatly influenced by crystal defects, which are, in turn, used to control these properties. However, experimental quantification of the density of defects, whether deliberately introduced or inherent, is very difficult in these atomically thin materials. Here we show that helium atom micro-diffraction can be used to measure the defect density in ~15x20um monolayer MoS2, a prototypical 2D semiconductor, quickly and easily compared to standard methods. We present a simple analytic model, the lattice gas equation, that captures the relationship between atomic Bragg diffraction intensity and defect density. The model, combined with ab initio scattering calculations, shows that our technique can immediately be applied to a wide range of 2D materials, independent of sample chemistry or structure. Additionally, wafer-scale characterization is immediately possible.

physics.app-ph

Compact Modeling of Oxide-Semiconductor, 2D Material, Carbon Nanotube, and Cryogenic Transistors with Experiment Verification

This paper presents a unified compact model for emerging transistor technologies, including oxide-semiconductor field-effect transistors (OSFETs), 2D material FETs (2DFETs), carbon nanotube FETs (CNFETs), and cryogenic MOSFETs. A unified charge-density formulation is developed to account for quantum confinement, trap charges, and band-tail states in channel charge calculations. A physics-based transport model is introduced to seamlessly capture carrier transport from the long-channel diffusive regime to the short-channel ballistic limit. Scaling models are incorporated to accurately describe 2D electrostatic effects. Cryogenic operation is modeled through the inclusion of band-tail states and temperature-dependent mobility and threshold voltage. The proposed model is validated against experimental data from the fabricated OSFETs with multiple channel lengths and published measurements of 2DFETs, CNFETs, and cryogenic MOSFETs. Excellent agreement is demonstrated across diverse device architectures, operating conditions, and material systems.

physics.app-ph

Multiplexing approaches to thermoradiative signatureless communications

Using mid-infrared emission from semiconductor devices for covert communications remains a relatively unexplored and yet promising opportunity. The phenomenon of negative luminescence allows for a method of signatureless covert communications where the net infrared emission of an emitting optoelectronic device is balanced to be identical to the ambient thermal background. In this work we provide a practical demonstration of covert data transfer over a thermoradiative channel with data rates up to 100 kbps. In addition, we demonstrate several additional multiplexing techniques that make the proposed thermoradiative communications method more secure against interception by achieving zero instantaneous optical emission, while remaining detectable if a sufficiently spatially or spectrally discerning observation is utilised. Finally, we discuss various application scenarios in which the proposed methods can be used to achieve secure signatureless communications.

physics.app-ph