Search arXivSearch

arXiv · 2608.23511

Post-diffusion cooling effects on Hall-derived active lithium donor profiles in high-purity germanium

Abstract

Lithium (Li) diffusion is commonly used to form $n^{+}$ contacts in high-purity germanium (HPGe) detectors, but the final electrically active donor profile can be sensitive to the post-diffusion thermal history. Li was introduced into HPGe coupons using a lithium-in-oil suspension and diffused for $30~\mathrm{min}$ at nominal temperatures of $240$--$310~^{\circ}\mathrm{C}$. Short- and long-cooling protocols were documented by measured witness-Ge cooling histories. Sequential material removal combined with Hall-effect measurements at $77~\mathrm{K}$ was used to reconstruct difference-derived apparent Hall donor profiles. Because Hall response in a nonuniform conducting layer is mobility weighted, these profiles are operational electrically active-donor metrics rather than direct local or total-Li concentration profiles. Complementary-error-function fits were used to obtain the extrapolated apparent intercept $N_{s,\mathrm{app}}$ and the apparent profile-width parameter $D_{\mathrm{app}}$. For the coupons studied, short cooling was associated with larger $N_{s,\mathrm{app}}$ and sharper profiles, whereas long cooling was associated with lower $N_{s,\mathrm{app}}$ and broader low-concentration tails. Fit-derived concentration-threshold depths likewise extended farther into the Ge bulk for the long-cooling coupons. These results show that the complete post-diffusion thermal history should be considered when parameterizing Hall-active Li-diffused $n^{+}$ contacts for HPGe detector fabrication.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kunming Dong, Dongming Mei, Anupama Karki, Partrick Burns, Sanjay Bhattarai. 2026-08-24. Post-diffusion cooling effects on Hall-derived active lithium donor profiles in high-purity germanium. https://arxiv.org/abs/2608.23511

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det