Search arXivSearch

arXiv · 2608.24289

Demonstration of simultaneous PIAA- coronagraphy and wavefront sensing using a single metasurface-based focal-plane optic

Abstract

Controlling residual wavefront aberrations downstream of an extreme adaptive optics (ExAO) system is a major challenge in high-contrast imaging. These aberrations produce quasi-static speckles due to differences between the wavefront-sensing and science paths. Highly sensitive wavefront sensors, such as Zernike wavefront sensors (ZWFSs), are used to mitigate these non-common path aberrations. High-performing coronagraphs, such as complex mask coronagraphs (CMCs), are also implemented in the focal plane. Both perform better with lossless apodization such as phase-induced amplitude apodization (PIAA) optics. Metasurfaces can have chromatic responses, allowing a single focal-plane optic to have different functionalities in different wavelength bands. We demonstrate such an optic by manufacturing a hybrid metasurface designed to function as a CMC and a ZWFS in two intermediate-band filters in the H band, each with a fractional bandwidth of approximately 1\%. We show measured optical responses with phases of $\sim π/2$ at shorter wavelengths and $π$ at longer wavelengths between $1500$ and $1700,\text{nm}$. This would allow for wavefront sensing at the shorter wavelength of $\sim1500\,\text{nm}$ and coronagraphy at the longer wavelength of $\sim1700\,\text{nm}$. Additionally, we tested the mask on-sky with the MagAO-X instrument at the Magellan Clay 6.5 m telescope at Las Campanas Observatory, Chile. On-sky results show a contrast of $\sim 10^{-1}$ at a non-ideal wavelength of $\sim 1600\,\text{nm}$. This is comparable to simulated contrast curves using the measured optical responses around that wavelength. Finally, we evaluated the wavefront-sensing performance of the metasurface using the MagAO-X internal source at $1300\,\mathrm{nm}$. The measured reconstruction error is consistent with simulations of an ideal Zernike wavefront sensor, confirming its wavefront-sensing functionality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dhwanil Patel, Sebastiaan Y. Haffert, Skyler Palatnick, Adam Taras, Maxwell A. Millar-Blanchaer, Matthijs Mars, Elena Tonucci, Jared R. Males, Laird M. Close, Joshua Liberman, Warren B. Foster, Kyle Van Gorkom, Olivier Guyon, Alexander D. Hedglen, Parker T. Johnson, Maggie Y. Kautz, Jay K. Kueny, Jialin Li, Joseph D. Long, Jennifer Lumbres, Eden A. McEwen, Avalon McLeod, Lauren Schatz, Katie Twitchell, Robert J. Harris, Viktoria Kutnohorsky. 2026-08-25. Demonstration of simultaneous PIAA- coronagraphy and wavefront sensing using a single metasurface-based focal-plane optic. https://doi.org/10.1117/12.3100860

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Scale Contrastive Attention for Light-Curve Representation Learning

Current and next-generation time-domain surveys demand automated techniques capable of analyzing millions of light curves, observed in multiple filters, without relying on exhaustive human annotation or scarce spectroscopic follow-up. We present Astra-CLR, an attention-based, self-supervised contrastive learning framework which enables the representation of raw light curves into a highly discriminative latent space. Pre-trained on $\sim$2.1 million unlabeled Zwicky Transient Facility light curves, the framework utilizes partial light curves as input sequences to generate asymmetric, multi-scale temporal views (explicitly contrasting shorter sequences against longer ones) forcing the network to learn a robust "local-to-global" mapping strategy. Furthermore, we introduce a novel multi-view late fusion architecture that extends the model to efficiently handle longer light curves with larger numbers of observations while accommodating the different cadences associated with each filter. The discriminatory power of the resulting representations was evaluated by using them as input to a Multinomial Logistic Regression classifier, trained to identify 12 broad classes of variability. Final accuracy achieved $\sim 0.70$. When applying a label-efficient, partial top-layer fine-tuning strategy, the topological structure of the latent space is significantly refined, boosting results to $\sim$0.77. Astra-CLR is the first publicly available multi-filter time-series Transformer trained exclusively on real ZTF light curves. Results presented here demonstrate that it provides an ideal foundation for the development of end-to-end pipelines, taking into account color evolution and respecting the inhomogeneous nature of astronomical light curve sampling.

astro-ph.IM

Combining astrometry with pulsar timing: the first joint analysis of very low frequency gravitational waves

The pHz to sub-nHz GW regime remains largely unexplored but is crucial for mapping the early inspiral stage of SMBHBs and probing early-Universe physics. Astrometry and pulsar timing offer orthogonal and deeply complementary secular observables to investigate this frequency band. We aim to present the first joint data analysis combining real astrometric proper motions with binary pulsar timing, to search for and constrain continuous gravitational waves (CWs) sourced by SMBHBs in the ultra-low-frequency regime ($10^{-12} \le f_{GW} \le10^{-9} Hz$). We employ a Bayesian model selection and upper limit estimation framework to combine apparent proper motion displacements of $\sim 1.5 \times 10^6$ quasars from the Gaia CRF3 catalog with the line-of-sight orbital period derivatives ($\dot{P}_b$) of 11 high-precision binary pulsars. To prevent spurious detections, we heavily model instrumental and astrophysical systematics: we propagate the Galactic potential uncertainty for pulsars via Monte Carlo simulations and perform a Vector Spherical Harmonics (VSH) decomposition up to the octupole order (l=3) for quasars. We find no statistically significant evidence for a CWs signal in the joint analysis ($\ln B_{joint} = -0.42 \pm 0.03$). In the absence of detection, we set the tightest constraints to date on CW strain in the pHz band, yielding a 95% upper limit of $h_0\le6.4x10^{-11}$ at a reference frequency of $f_{ref} = 4 \times 10^{-10}$ Hz. The combined dataset achieves full sky coverage and improves single-dataset upper limits by 20%-30%. Combining orthogonal observables successfully breaks spatial degeneracies intrinsic to isolated searches. Furthermore, forecasts from inj.-rec. indicate that with the extended temporal baseline and reduced uncertainties of the upcoming Gaia DR4, this joint framework is poised to break the $h_0 < 10^{-11}$ upper limit barrier for sub-nHz CWs.

astro-ph.IM

Bayesian classification of astronomical spectra with class uncertainties

Context: We developed a probabilistic machine learning method with the aim of performing the O(10)-way classification of low- and high-resolution spectra of stellar and extragalactic targets for the upcoming 4MOST survey. In fulfilment of the survey requirements, this method should be able to express uncertainty in the input data as well as uncertainty introduced in its prediction. Aims: Four different methods are explored: (1) convolutional neural networks (CNNs), (2) the Dirichlet distribution, (3) Monte Carlo dropout (MCD), (4) Bayesian neural Networks (BNNs) + variational inference (VI). Training and validation was performed using labelled spectra from the SDSS database and a custom 4MOST mock dataset. All the methods were compared in terms of the same metrics: accuracy, area under the curve (AUC), expected calibration error (ECE), Shannon entropy, negative log-likelihood (NLL), Brier score, training time, and inference time. Methods: A CNN with simple architecture and about 20,000 parameters was trained to achieve classification accuracies of 91.5% on SDSS data and 92.8% on 4MOST mock data. The direct Dirichlet prediction and VI models tested provide uncertainties on class membership probabilities, but they confuse classes more often. The MCD on a CNN is found to be the most suitable; it boosts the point-estimate accuracies to 92.6% and 93.9%, while still providing fast training and sufficiently fast inference. Compared to a standard CNN, the method additionally provides well-calibrated uncertainties at marginal extra cost.

astro-ph.IM