Search arXivSearch

arXiv · 2608.30574

Exposing the Invisible: Detecting Stealthy Parameter-Based Cyber-Attacks on Inverter Synchronization Loops

Abstract

The increasing integration of Internet-of-Things (IoT) technologies for monitoring and control of inverter-based resources (IBRs) has expanded the attack surface, enabling stealthy manipulation of controller parameters through vulnerable supervisory control interfaces. Phase-locked loops (PLLs) emerge as prime targets, as they interact with all control loops and critically influence the dynamic response of grid-following (GFL) converters. This paper analyzes the underlying threat model to elucidate the mechanisms enabling such stealthy behavior and conducts a thorough stability and transient response analysis to characterize how PLL tampering can degrade system performance without necessarily destabilizing the system. The results reveal critical interactions among frequency estimation, control, and synchronization that can significantly reduce stability margins. To counter the stealthy nature of these attacks, a modified PLL is proposed that exposes gain variations through shifts in its equilibrium points while preserving conventional PLL performance. Experimental results validate the effectiveness of the proposed approach in detecting PLL cyber-attacks.

Explore related subjects

Keep this discovery

BibTeXRIS

Zaint A. Alexakis, Michal M. Drewniak, Charalambos Konstantinou. 2026-08-31. Exposing the Invisible: Detecting Stealthy Parameter-Based Cyber-Attacks on Inverter Synchronization Loops. https://arxiv.org/abs/2608.30574

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related papers

A simple derivation of the Kalman filter

In this lecture note, we present a concise and self-contained derivation of the discrete-time Kalman filter equations that requires only a basic understanding of least squares estimation. The treatment is designed to minimize mathematical overhead while preserving both rigor and generality.

math.OC

Relative-Degree Wall Restricts Passivity-Based Stability Analysis in Inverter-Dominant Grids

This letter reveals a fundamental limitation of passivity-based distributed stability analysis in power systems. Under the standard formulation, passivity certification inherently imposes a relative-degree compatibility constraint that excludes many high-fidelity inverter dynamic models (e.g., those that include electromagnetic transients). Potential extensions of passivity frameworks are discussed to break this limitation.

eess.SY