Dimension-Reduced ADP for Real-Time Microgrid Operation with Massive Air-Conditioning Loads under Multiple Uncertainties

Abstract

This paper proposes a dimension-reduced approximate dynamic programming (ADP) method for real-time microgrid operation with massive air-conditioning loads under multiple uncertainties. The operation problem is formulated as a multi-stage Markov decision process, and a post-decision value function is introduced to characterize the impact of current decisions on future operating costs. To address the curse of dimensionality caused by massive air-conditioning loads, a consistency-based value function projection is developed to map the high-dimensional state space at each node into a tractable aggregated state space. Based on the reduced states, piecewise linear approximation is further employed for efficient value function training. Case studies on 33-bus and 123-bus systems show that the proposed method achieves near-optimal operation performance with low computational cost and good scalability under both deterministic and stochastic conditions.

Explore related subjects

Keep this discovery

BibTeXRIS

Jingguan Liu, Xiaomeng Ai, Shichang Cui, Jiakun Fang, Jinyu Wen. 2026-09-02. Dimension-Reduced ADP for Real-Time Microgrid Operation with Massive Air-Conditioning Loads under Multiple Uncertainties. https://arxiv.org/abs/2609.01972

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related papers

A simple derivation of the Kalman filter

In this lecture note, we present a concise and self-contained derivation of the discrete-time Kalman filter equations that requires only a basic understanding of least squares estimation. The treatment is designed to minimize mathematical overhead while preserving both rigor and generality.

math.OC

Relative-Degree Wall Restricts Passivity-Based Stability Analysis in Inverter-Dominant Grids

This letter reveals a fundamental limitation of passivity-based distributed stability analysis in power systems. Under the standard formulation, passivity certification inherently imposes a relative-degree compatibility constraint that excludes many high-fidelity inverter dynamic models (e.g., those that include electromagnetic transients). Potential extensions of passivity frameworks are discussed to break this limitation.

eess.SY