Search arXivSearch

arXiv · 2609.02838

Tests on the POD-P controller of INELFE Spain-France VSC-HVDC interconnector

Abstract

INELFE interconnector consists of a 2x1000 MW high voltage direct current system based on voltage source converters (VSC-HVDC) interconnecting France and Spain. INELFE VSC-HVDC link is embedded into the high voltage alternating current (HVAC) system. Electromechanical oscillations, also known as power oscillations, are a major concern worldwide. INELFE VSC-HVDC link has specific controllers to damp power oscillations by modulating active (P)- and reactive (Q)-power injections of the VSC converters (POD-P and POD-Q controllers, respectively). The Spanish and French Transmission System Operators (TSOs) carried out a join task force to - Increase the gain of POD-P controller of INELFE VSC-HVDC link. - Make it possible to use the POD-P controller together with angle difference control (ADC) of INELFE VSC-HVDC interconnector. The objective of these modifications is to improve the effectiveness of POD-P controller and, therefore, to increase its contribution to the damping of inter-area oscillations in the Continental Europe (CE) power system. Such changes require (a) extensive simulation studies and (b) extensive tests in different operation modes, in order to ensure the correct behavior of the system. This paper presents simulation studies and field tests on the POD-P controller of INELFE VSC-HVDC interconnector in different modes of operation.

Explore related subjects

Keep this discovery

BibTeXRIS

Javier Renedo, Agustín Diaz-García, Gilles Torresan, Eduardo Lorenzo Cabrera, Antonio Cordón, Silvia Sanz Verdugo, Juan Peiró, Javier Pérez Castro, Gorka Calvo, Aitor Hernández Sautua, Ambroise Petit, Hamza Oukhayi, Samy Akkari, Hani Saad. 2026-09-02. Tests on the POD-P controller of INELFE Spain-France VSC-HVDC interconnector. https://arxiv.org/abs/2609.02838

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related papers

A simple derivation of the Kalman filter

In this lecture note, we present a concise and self-contained derivation of the discrete-time Kalman filter equations that requires only a basic understanding of least squares estimation. The treatment is designed to minimize mathematical overhead while preserving both rigor and generality.

math.OC

Relative-Degree Wall Restricts Passivity-Based Stability Analysis in Inverter-Dominant Grids

This letter reveals a fundamental limitation of passivity-based distributed stability analysis in power systems. Under the standard formulation, passivity certification inherently imposes a relative-degree compatibility constraint that excludes many high-fidelity inverter dynamic models (e.g., those that include electromagnetic transients). Potential extensions of passivity frameworks are discussed to break this limitation.

eess.SY