Search arXivSearch

arXiv · 2609.09962

A unified quantum electrical platform for synchronous metrological realization of volt, ohm and ampere

Abstract

A co-located integration quantum electrical standard is essential to reduce reliance on distributed traceability in high-accuracy metrology, especially for portable and on-site use. Metrologically, realizing any two of voltage, resistance, and current is sufficient, as the third follows from Ohm's law. The combination of Josephson voltage and quantum Hall resistance offers better uncertainty, but conflicts with the tesla-level field for quantum Hall and near-zero field for Josephson operation. Here we report a compact unified platform enabling co-realization of quantum voltage and resistance in a single cryostat near 4 K, with quantum current derived via Ohm's law. A hierarchical magnetic shielding with staged attenuation and spatial confinement allows 6 T and below 50 nT to coexist within 270 mm axial separation with negligible cross-coupling. In integrated operation, the Josephson and quantum Hall subsystems agree with expected quantized values within relative standard uncertainties of 2.6E-9 and 1.4E-8, respectively. Linking them via an improved cryogenic current comparator realizes a 50 μA quantum current with relative uncertainty of 6.6E-8. These results demonstrate that three basic electrical units can be synchronously realized with superior metrological consistency on a single integrated platform, offering a viable transition from distributed calibration chains toward compact-integrated quantum-based realization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lei Wang, Lushuai Qian, Yunfeng Lu, Yang Shi, Xuanlu Yang, Xiaoding Huang, Zihan Lei, Yuan Zhang, Yaqiong Fu, Junsheng Cheng, Jianhua Liu, Xinning Hu, Yinming Dai, Jianting Zhao, Qiuliang Wang. 2026-09-09. A unified quantum electrical platform for synchronous metrological realization of volt, ohm and ampere. https://arxiv.org/abs/2609.09962

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det