Post-fabrication trimming of a 1024-pixel, single-photon counting, Microwave Kinetic Inductance Detector array with a pixel pitch of 150 micron

Abstract

Microwave Kinetic Inductance Detectors are superconducting resonators capable of single-photon counting with energy resolving capability at visible and near-infrared wavelengths. Their zero read noise, extremely low dark counts, and compatibility with frequency-division multiplexing make them well suited for large imaging arrays. The detector yield of these arrays is often limited by the fabrication-induced frequency scatter leading to resonator collisions. We find that the tight packing of the pixels can add significant frequency scatter as well. We developed a post-fabrication correction method that is suitable for tightly packed arrays with a pixel pitch of $150\ \mathrm{μm}$. We demonstrate this method on a 1024-pixel array multiplexed on a single octave of readout bandwidth and show a reduction in frequency scatter from $1.1\times 10^{-2}$ to $3.5\times 10^{-4}$ and an increase in yield from $76\%$ to $94\%$.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wilbert Ras-Vinke, Hessel Schulte, David J. Thoen, Kevin Kouwenhoven, Steven A. H. de Rooij, Tonny A. H. M. Coppens, Jochem J. A. Baselmans, Pieter J. de Visser. 2026-09-09. Post-fabrication trimming of a 1024-pixel, single-photon counting, Microwave Kinetic Inductance Detector array with a pixel pitch of 150 micron. https://arxiv.org/abs/2609.10146

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det