Search arXivSearch

arXiv · 2609.11758

RAG-Safety-Bench: Reliable Evaluation of Retrieval-Augmented LLM Safety

Abstract

Allowing large language models (LLMs) to retrieve information from a set of trusted documents can increase reliability and reduce hallucination. However, recent work has demonstrated that retrieval-augmented generation (RAG) can have unintended side effects on the overall safety of the generated responses, when prompted for harmful or dangerous content. A clearer understanding of the mechanisms leading to this result is needed, as increasing numbers of end users turn to RAG to incorporate corporate documents and knowledge bases into LLM-based systems. We introduce RAG-Safety-Bench, a benchmark to measure the safety impact of RAG on LLM models. By removing the confounding effect of retriever quality, and cleanly separating the problem into four conditions -- non-RAG, RAG with an oracle document containing the answer to the harmful request, RAG with documents related to the harmful request but without the specific answer, and RAG with random, safe documents -- the benchmark isolates the impacts of different factors in the observed safety degradation. We report results across five open-source LLMs, showing an inverse relationship between benign and unsafe capability, strong evidence that baseline safety guardrails do not lead to downstream safety guarantees in the RAG case, and model-specific support for previous findings that even benign documents can lead to unsafe generation in retrieval-enabled systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Adithiyan Rajan Indira Saravanan, Kathleen C. Fraser. 2026-09-10. RAG-Safety-Bench: Reliable Evaluation of Retrieval-Augmented LLM Safety. https://arxiv.org/abs/2609.11758

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

SafetyFlow: An Agent-Flow System for Automated LLM Safety Benchmarking

The rapid proliferation of large language models (LLMs) has intensified the requirement for reliable safety evaluation to uncover model vulnerabilities. To this end, numerous LLM safety evaluation benchmarks are proposed. However, existing benchmarks generally rely on labor-intensive manual curation, which causes excessive time and resource consumption. They also exhibit significant redundancy and limited difficulty. To alleviate these problems, we introduce SafetyFlow, the first agent-flow system designed to automate the construction of LLM safety benchmarks. SafetyFlow can automatically build a comprehensive safety benchmark in only four days without any human intervention by orchestrating seven specialized agents, significantly reducing time and resource cost. Equipped with versatile tools, the agents of SafetyFlow ensure process and cost controllability while integrating human expertise into the automatic pipeline. The final constructed dataset, SafetyFlowBench, contains 23,446 queries with low redundancy and strong discriminative power. Our contribution includes the first fully automated benchmarking pipeline and a comprehensive safety benchmark. We evaluate the safety of 49 advanced LLMs on our dataset and conduct extensive experiments to validate our efficacy and efficiency.

cs.CL

Geometric Uncertainty for Detecting and Correcting Hallucinations in LLMs

Large language models are known to hallucinate, generating linguistically plausible but incorrect answers to questions. Uncertainty quantification has been proposed as a strategy to detect such behaviour, but existing methods lack a unified framework to assess reliability at both the prompt and answer level. We introduce a geometric framework which quantifies language model uncertainty at both levels by explicitly modelling a prompt-conditioned semantic distribution in answer embedding space. Our approach is black-box and sampling-based; we generate multiple answers per prompt, and use archetypal analysis to estimate a geometric support for the answer distribution. At the prompt level, we approximate the distribution entropy to quantify uncertainty; for each individual answer, we then use notions of atypicality to assess its reliability relative to the batch. We employ our framework to not only detect hallucinations but correct them, by selecting the batch example deemed most reliable. Experiments show that our framework performs comparably to or better than prior methods on short form question-answering datasets, and achieves superior results on medical datasets where hallucinations carry particularly critical risks. Beyond pure performance, we suggest the theoretical grounding of our work provides support for semantic distributions as useful objects of study for language model uncertainty.

cs.CL

Calibrated Confidence Expression for Radiology Report Generation

Safe deployment of Large Vision-Language Models (LVLMs) in radiology report generation requires not only accurate predictions but also clinically interpretable indicators of when outputs should be thoroughly reviewed, enabling selective radiologist verification and reducing the risk of hallucinated findings influencing clinical decisions. One intuitive approach to this is verbalized confidence, where the model explicitly states its certainty. However, current state-of-the-art language models are often overconfident, and research on calibration in multimodal settings such as radiology report generation is limited. To address this gap, we introduce ConRad (Confidence Calibration for Radiology Reports), a reinforcement learning framework for fine-tuning medical LVLMs to produce calibrated verbalized confidence estimates alongside radiology reports. We study two settings: a single report-level confidence score and a sentence-level variant assigning a confidence to each claim. Both are trained using the GRPO algorithm with reward functions based on the logarithmic scoring rule, which incentivizes truthful self-assessment by penalizing miscalibration and guarantees optimal calibration under reward maximization. Experimentally, ConRad substantially improves calibration and outperforms competing methods. In a clinical evaluation we show that ConRad's report level scores are well aligned with clinicians' judgment. By highlighting full reports or low-confidence statements for targeted review, ConRad can support safer clinical integration of AI-assistance for report generation.

cs.CL