Search arXivSearch

arXiv · 2609.13107

Spectro-polarimetry of HAbitable Planet Earth (SHAPE) on Chandrayaan-3: Instrument characteristics, calibration and onboard performance

Abstract

The orbiter of the Chandrayaan-3 mission of the Indian Space Research Organisation (ISRO) carries an experimental payload called SHAPE (Spectro-polarimetry of HAbitable Planet Earth). This payload makes disc-integrated observations of Earth as an exoplanet, from the Moon as well as from the high altitude Earth orbit. The instrument consists of an Acousto-Optic Tunable Filter (AOTF) based near-infrared spectro-polarimeter making the measurements in the two orthogonally polarized directions using a pair of Indium-Gallium-Arsenide (InGaAs) detectors. The laboratory characterization of the flight model of the instrument included a relative measurement of the response of the two channels of the instrument. The field measurements of the instrument revealed a non-uniformity in the field response. In the light of non-identical response of the two channels and the non-uniformity of the field response, a theoretical model of such a polarimeter is developed to gain insights into the performance of a polarimeter. Analysis of lunar observations obtained within the SHAPE field of view indicates that the transmission ratio between the two polarized channels lies in the range 0.8-1.2. Such deviations from unity can introduce offsets in the measured polarization of up to about 10%. The suitability of SHAPE for studying the band polarization, defined as the relative polarization within a spectral absorption band, is studied. Using the Moon observations and the theoretical instrumental model, the suitability of measuring the relative band polarization is demonstrated. A study of systematic biases in the band polarization demonstrates a maximum offset of less than 1% in the measured value of the band polarization. The initial results of Earth observations, spectra and flux measurements across phase angles, and the methodology for retrieving the band polarization from these observations are also discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bhavesh Jaiswal, Swapnil Singh, Ravishankar B T, Anand Jain, Smrati Verma, Reenu Palawat, Brajpal Singh, Bijoy Raha, Sathyanarayana Raju, Bhavesh Mendhekar, Srinivasa Rao Kondapi, Priyanka Das, Rahul Waghmare, Supratik Bose, Supriya Verma, Yogesh Prasad K R, Praloy Karmakar, Abhishek Kumar Singh, Honey Gupta, Balaraman Prabakaran, Motamarri Srikanth, Sankarasubramanian Kasiviswanathan, Anuj Nandi. 2026-09-11. Spectro-polarimetry of HAbitable Planet Earth (SHAPE) on Chandrayaan-3: Instrument characteristics, calibration and onboard performance. https://arxiv.org/abs/2609.13107

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM