Search arXivSearch

arXiv · 2609.14661

Constraint-Traceable Liquid-Nitrogen Dewar Design for Low-Noise HTS-SQUID Magnetometry

Abstract

Compact high-temperature superconducting quantum interference device (HTS-SQUID) magnetometers require a liquid-nitrogen Dewar that balances operating duration against instrument-envelope and mass constraints. Here we introduced a constraint-traceable design workflow in which body radius and neck-length fraction were scanned under fixed outer-envelope volume and geometry-based mass limits. The longest-duration feasible grid point lay adjacent to the 3.85 kg and 550 mm constraint intersection, predicting 224 h hold time from a body-only initial fill to a residual liquid depth of 10 mm. A reference Dewar was experimentally monitored for 137.3 h, consuming 1.22 L liquid-nitrogen of its initial inventory. A thermal model calibrated over the first 40 h reproduced the remaining 97.3 h. Device measurements at liquid-nitrogen temperature showed a superconducting transition and Fraunhofer-like junction response, a maximum voltage-modulation depth of 36.2 $μ$V, and a median noise level of 41.5 fT Hz$^{-1/2}$ from 100 to 1000 Hz. These results establish a reproducible method for selecting Dewar geometry under coupled constraints and demonstrate compatibility with long-endurance and low-noise HTS-SQUID magnetometer systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Xinmin Shi, Bingke Xiang, Lingtong Hou, Wanjuan Tang, Geming Zhang, Shiqun Liu, Ruonan Wang, Yibo Wang, Zhiqiang Cao, Xueshen Wang, Xueying Zhang, Xiaoyang Lin. 2026-09-13. Constraint-Traceable Liquid-Nitrogen Dewar Design for Low-Noise HTS-SQUID Magnetometry. https://arxiv.org/abs/2609.14661

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det