arXiv · 2609.20136
Reconstruction of Beam Transverse Parameters in the Fermilab Side-Coupled Linac Using a Normalized Coordinate Framework
Abstract
Quadrupole scans are a commonly used tool for beam second moment reconstruction. Limitations in the strength of the magnets and layout of the beamline elements frequently preclude simple quadrupole-drift-detector scans from collecting sufficient data for reconstruction. Using a normalized coordinate framework, we characterize the prerequisites for a robust simple quadrupole scan and expand these prerequisites to reconstruction from more complex optics. The beam second moments are investigated at two locations in the Fermilab Side-Coupled Linac under simple and complex optics, using this framework to maximize information gained from wire scanner profile measurements.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
E. V. Chen, J-P. Carneiro, R. V. Sharankova, A. V. Shemyakin. 2026-09-17. Reconstruction of Beam Transverse Parameters in the Fermilab Side-Coupled Linac Using a Normalized Coordinate Framework. https://arxiv.org/abs/2609.20136
Cite the original work for its findings. Save a collection to share your selection of sources.