Search arXivSearch

arXiv · 2609.20552

Mineral Detection of Neutrinos and Dark Matter 2026 Proceedings

Abstract

The fourth "Mineral Detection of Neutrinos and Dark Matter" (MDvDM'26) meeting was held April 14-17, 2026 in Karlsruhe, Germany, hosted by the Institute for Astroparticle Physics (IAP) at Karlsruhe Institute of Technology (KIT). These proceedings detail the contributions that were presented during MDvDM'26, illustrating the unprecedented progress in theoretical, computational and experimental studies towards the realization of the concept of mineral detectors. Mineral detectors represent an emerging particle detection concept that has risen in prominence in recent years due to the advent of modern computational and high-resolution microscopy techniques. Natural and synthetic crystals are capable of retaining microscopic damage features induced by nuclear recoils, which could be then read out with a variety of micrometer and nanometer resolution microscopy techniques. On laboratory time scales mineral detectors could be employed for reactor neutrino monitoring and dark matter detection, with the potential to measure the directions as well as the energies of the induced nuclear recoils. Uniquely, ancient natural crystals (so-called paleo-detectors) that have been recording nuclear recoils over geological timescales could be used for studying astrophysical neutrinos, cosmic rays, dark matter and heavy exotic particles, as well as the variation of their fluxes over our Galaxy's lifetime. In recent years the international MDvDM community has been successfully tackling the challenges associated with realizing the concept of mineral detectors, opening the pathway towards a fully fledged experimental program and potential future discoveries.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alexey Elykov, Patrick Stengel, Natsue Abe, Daniel Ang, Lorenzo Apollonio, Levente Balogh, Laura Baudis, Chinmay Bharathulwar, Priyanshu Bhattacharya, Yilda Boukhtouchen, Joseph Bramante, Vincent Breton, Andrew Buchanan, Jens Burkhart, Lorenzo Caccianiga, Andrew Calabrese-Day, Mason Camp, Jordan Chapman, Anson Cook, Reza Ebadi, Denis Erkal, Katherine Freese, Audrey Fung, Shota Futamura, Claudio Galelli, Kevin Gao, Peter W. Graham, Thomas Haddock, Minako Hashiguchi, Alexander Hayes, Adam A. Hecht, Samuel C. Hedges, Shigenobu Hirose, Luisa M. Hötzsch, Patrick Huber, Yohei Igami, Vsevolod Ivanov, Florian Jörg, Ayuki Kamada, Takenori Kato, Yoji Kawamura, Katharina Kehl, Chris Kelso, Holger Kluck, Emilie M. LaVoie-Ingram, Matthew Leybourne, Gavishta H. M. Liyanage, Thalles Lucas, Brenden A. Magill, Paolo Magnani, Jennika McIntosh, Naoki Mizutani, Kohta Murase, Tatsuhiro Naka, Lina Necib, Pranav Parvathaneni, Andre Peterson, Zachary S. C. Picker, Rabeya Rabu, Harikrishnan Ramani, Anupam Ray, Morteza Roostaeinia, Hannah Ross, Issei Saikyo, Lukas Scherne, Maximilian Shen, Aaron Shugar, Joshua Spitz, Kai Sun, Jiashen Tang, Erwin H. Tanin, Dionysios P. Theodosopoulos, Yoichi Usui, Pieter Vermeesch, Aaron Vincent, Ronald Walsworth, Jin-Wei Wang, David Waters, Samuel S. Y. Wong, Audrey Wu, Gregory Wurtz, Wen Yin, Xiuyuan Zhang, Zhexian Zhang. 2026-09-17. Mineral Detection of Neutrinos and Dark Matter 2026 Proceedings. https://arxiv.org/abs/2609.20552

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mortality of ultra-thin LGADs and PiN diodes from high energy deposition

Low Gain Avalanche Diodes are prime candidates for high-resolution timing applications in High Energy Physics, Nuclear science, and several other fields. Operating these devices in high-radiation environments presents various hazards, including the risk of their permanent degradation or destruction caused by effects such as Single Event Burnout. Studies using minimum ionizing particles found a greatly reduced Single Event Burnout risk by operating below a bias voltage corresponding to an average electric field of 12 V/$μ$m - however, as high energy particle colliders produce a wide energy spectrum of radiation, it is crucial to understand this phenomenon and other possible damage mechanisms at energy deposition levels greater than those of minimum ionizing particles. This was achieved by pre-irradiating LGADs and PiN diodes with active thicknesses of 20, 30, and 50 $μ$m up to 1.5 $\times$ 10$^{15}$ $\mathrm{n_{eq}/cm^2}$, and exposing them to beams of protons and heavy ions (C, O, Fe, Au) at the BNL Tandem van de Graaff accelerator. Several mortality categories were observed, defined by different electrical and mechanical damage signatures. This furthers our understanding of permanent radiation damage of silicon devices, crucial towards mitigating Single Event Burnout and other damage mechanisms to safely operate future detectors.

physics.ins-det

Small but Tubby: A Magnetic Loop Antenna Made from 100 mm Copper Tubing

This paper presents the electrical model, key equations, and practical construction of a small transmitting magnetic loop antenna built from unusually large 100 mm diameter copper tubing. The large conductor surface area and wide-area transitions to the vacuum capacitors were designed to minimize resistive losses. The frequency range from 1.8 MHz to 31 MHz is unusually wide. Frequency, impedance matching, and azimuth are all adjusted automatically by servo motors. Indoor losses originate predominantly from near-field coupling to the environment rather than from the antenna itself. Temperature-rise measurements confirm that the bulk of the dissipated power is absorbed by the environment, not by the antenna components. The conducted H-field measurements demonstrate good agreement between the measured H-field and the theoretical free-space H-field calculated from the antenna geometry and an estimated loop current. The loop current was estimated from the measured antenna bandwidth and the applied transmit power. The antenna was developed for indoor operation where outdoor installation is not possible.

physics.ins-det

Construction and characterisation of the DarkSide-20k veto silicon photo-multiplier tiles

Silicon photo-multipliers (SiPMs) are state-of-the-art sensors capable of detecting a single photoelectron under cryogenic conditions, with potentially lower radioactivity than widely used photomultiplier tubes. The DarkSide-20k experiment, designed to perform direct dark matter searches using liquid argon as the target material, employs SiPM technology to detect interactions in the active detector volumes, including the central dual-phase Time Projection Chamber and the Inner and Outer Veto volumes. The vetoes are designed to discriminate against radiogenic neutron and cosmic muon backgrounds associated with the dark matter search. This paper describes the completed production and test protocols for the "Veto Tiles" (called vTiles, arrays of 24 SiPMs integrated on a printed circuit board providing the power distribution and signal amplification); 16 vTiles are grouped into "Veto Photo-Detector Units" to instrument the Inner Veto volume. Each vTile underwent detailed testing at room and cryogenic temperatures, confirming stable operation, high signal-to-noise ratio, and low radioactive contamination, demonstrating the robustness of the proposed design for cryogenic conditions. The final production yield exceeded 87%, surpassing the 80% requirement and corresponding to 1920 Veto Tiles to populate 120 Veto Photo-Detector Units, plus an additional 6% as spares.

physics.ins-det