Search arXiv⌕ Search

arXiv · 2609.29253

Scalable photoacoustic tomography implementations accounting for the spatial impulse response of transducers

Abstract

Iterative model-based reconstruction in photoacoustic tomography repeatedly applies the forward operator mapping the initial pressure to the transducer signals, and its adjoint. At the scale of current three-dimensional systems, this operator cannot be stored and must be evaluated matrix-free, while accounting for the finite, focused surface of the transducers, whose spatial impulse response degrades the resolution when ignored. Representing the initial pressure by compactly supported radial functions, we show that the measured signal is exactly a temporal convolution between a system kernel gathering the radial function and the electrical impulse response, and a purely geometric quantity accounting for the portion of the transducer surface reached by the wave emitted from a voxel during one time step. Two implementations are proposed, differing only in how this quantity is evaluated: a quadrature over points of the surface, as in existing works, or a closed-form area, which never discretizes the surface. We derive closed forms for planar and cylindrically focused transducers and provide, in the latter case, two accelerations of the resulting elliptic integrals, a lookup table and a trapezoidal approximation, together with the piecewise planar approximation customary in the literature. These implementations reduce the per-voxel geometric computations and are released as an open-source Python package for graphics processing units. The performance of these operators is first demonstrated on a synthetic phantom, where the lookup-table-based operator reaches the accuracy of the exact evaluation ten times faster and outperforms the point discretization on both accuracy and runtime. A second experiment shows that they enable the processing of a realistic vascular phantom at full scale, with a higher peak signalto-noise ratio and a better resolution than the back-projection counterpart. The released implementations are an important step towards the adoption of three-dimensional modelbased photoacoustic reconstructions with finite and focused transducers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Trung-Thai Do, Paul Escande, Caroline Chaux, Jérôme Gateau, Hwee Kuan Lee. 2026-09-24. Scalable photoacoustic tomography implementations accounting for the spatial impulse response of transducers. https://arxiv.org/abs/2609.29253

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Bridging the Inter-Domain Gap through Low-Level Features for Cross-Modal Medical Image Segmentation

This paper addresses cross-modal medical image segmentation, focusing on MRI-CT transfer in a source-only domain generalization setting. During training, only source-modality samples are available, while unlabeled target-modality images are used for testing. We propose LowBridge, which builds on the observation that cross-modal images share similar low-level features (e.g. edges) as they depict the same types of anatomical structures. Specifically, we first train a generative model to recover the source images from their edge features, followed by training a segmentation model on the generated source images, separately. At test time, edge features from the target images are input to the pretrained generative model to generate source-style target domain images, which are then segmented using the pretrained segmentation network. Experiments on various public datasets demonstrate that LowBridge achieves state-of-the-art performance, outperforming ten existing approaches. Ablation studies further show that LowBridge is compatible with different types of generative and segmentation models, suggesting its generalizability and potential to benefit from future advances in these models. The code will be available at https://github.com/JoshuaLPF/LowBridge.

eess.IV↗

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

eess.IV↗

LC3EM: Long-Range Context Extrapolation Enhanced Entropy Model for Coordinate-based Overfitting Image Codecs

Coordinate-based overfitting image codecs have attracted increasing attention for their low decoding complexity and independence from cross-image generalization. However, representative approaches such as COOL-CHIC face an inherent entropy-modeling trade-off: lightweight models have limited capacity, while more expressive ones incur additional bitrate overhead from transmitting image-specific parameters. Inspired by the prediction mechanism in traditional codecs, we propose a new entropy-modeling strategy that introduces complementary prediction modes with region-adaptive soft mode selection, rather than relying on a single learned predictor to model diverse types of redundancy. Based on this concept, we develop a Long-Range Context Extrapolation Enhanced Entropy Model (LC3EM), which can be integrated into coordinate-based overfitting codecs. Specifically, a parameter-free Neighborhood-based Linear Extrapolation Mode (NLEM) complements the tiny MLP-based local predictor to exploit long-range contextual redundancy and strongly directional structures. A Minimum-Entropy-Inspired Continuous Mode Selection strategy is designed to adaptively fuse these two complementary modes, while requiring the transmission of only the parameters of a single additional linear layer. Moreover, to alleviate the mismatch between training-time relaxed and actual discrete quantization, we introduce a lightweight iterative latent rounding refinement stage to improve compression performance. Experiments demonstrate consistent improvements across diverse benchmarks, particularly on highly regular computer-generated images. When integrated with COOL-CHIC 4.0, the proposed method achieves BD-rate gains of -3.43\% and -7.69\% on the SIQAD and API datasets, respectively. With COOL-CHIC 5.0 as the backbone, the corresponding gains are -2.88\% and -3.15\%, respectively. The code will be made publicly available soon.

eess.IV↗