High-spatial resolution, high-quality white matter tractography using DTI with dynamic slice-by-slice B0 shimming in a head-only high-gradient performance 3T MRI scanner

Abstract

Data from conventional diffusion tensor imaging (DTI) using single-shot echo planar imaging (SS-EPI) acquisition are substantially influenced by magnetic field inhomogeneities (delta B0), which result in image distortion and signal dephasing. Multi-shot EPI can mitigate the delta B0-induced artifacts but at the cost of increased scan time. Recent brain tissue-selective, dynamic slice-by-slice B0 shimming techniques have demonstrated effective reduction of local delta B0 in the brain. When combined with DTI utilizing an echo-planar imaging (EPI) read-out, image distortion and signal dephasing are significantly reduced. The purpose of our study was to assess the impact of DTI with dynamic slice-by-slice B0 shimming technique (DySiBo) on white matter (WM) tractography. We retrospectively analyzed DTI datasets using SS-EPI and Multi-shot EPI with 2 shots (MS-2shot-EPI) readout at two spatial resolutions (1x1x2mm3 and 2x2x2mm3) with and without DySiBo. WM tractography was generated and inspected to examine the impact upon regions typically affected by delta B0-induced artefacts. We found more WM streamlines were generated in the DTI datasets with DySiBo in regions conventionally impacted by delta B0-induced in EPI images, including the brainstem, temporal and frontal lobes. DySiBo substantially improved the generation of WM streamlines in DTI-based tractography at both in-plane resolutions. In conclusion, DySiBo in conjunction with DTI requiring 10 diffusion tensor directions is sufficient to generate data with high enough SNR and angular resolution to resolve crossing fibers and produce high quality WM tractography in brain regions typically affected by susceptibility-induced artefacts. This has implications for quantitative WM microstructural indices and clinical evaluation of WM tracts in patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jerome J. Maller, Patricia Lan, Sherry Huang, Chitresh Bhushan, Xinzeng Wang, Ante Zhu, Vincent A. Magnotta. 2026-09-28. High-spatial resolution, high-quality white matter tractography using DTI with dynamic slice-by-slice B0 shimming in a head-only high-gradient performance 3T MRI scanner. https://arxiv.org/abs/2609.36185

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Deep preferential evolution guided by pairwise comparisons enables motion correction in photoacoustic tomography

Motion artifacts in three-dimensional photoacoustic tomography (PAT), caused by extended mechanical scanning of sparse arrays, degrade image quality. Since sparse sampling results in low-quality sub-reconstructions, tracking motion directly is challenging. While final image quality could in principle guide artifact correction, conventional regularizers do not accurately reflect photoacoustic image quality. Here, we introduce deep preferential evolution (DPE), a derivative-free optimization framework where a learned image comparator guides evolutionary search over reconstruction parameters. By learning relative quality differences between same-target image pairs rather than absolute quality scores, the comparator generalized more robustly from simulation to in-vivo images (after unlabeled domain calibration) than an absolute scorer. Comparator-based DPE successfully corrected synthetic motion across diverse anatomies and backgrounds, and it mitigated artifacts from natural, unconstrained motion in human palm images. These results demonstrate that pairwise learned comparison can provide a transferable optimization objective for high-dimensional image restoration when labeled experimental training data are scarce.

physics.med-ph↗

Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector

In the context of range monitoring for particle therapy, this study presents the first experimental results obtained with the TIARA detector using carbon-ion beams at the CNAO clinical center in Pavia, Italy. TIARA is based on the Prompt Gamma Timing (PGT) technique, which measures the time of flight (TOF) between incident ions and prompt gamma rays (PGs) emitted during nuclear interactions in the target. While the TIARA prototype has previously been validated with protons, carbons present a more challenging scenario due to their higher linear energy transfer, nuclear fragmentation products, and the continuous beam time structure of synchrotron accelerators. Experiments were performed by irradiating PMMA targets of different thicknesses with 200 MeV/u carbon beams. A coincidence time resolution of 279$\pm$35 ps FWHM was achieved, outperforming results previously obtained with protons at the same facility. A range accuracy of 4.74$\pm$0.36 mm at a 2$σ$ confidence level was measured at clinical intensity, when considering 5600 detected PGs, corresponding to the grouping of four irradiation spots of 2.4$\cdot$10$^6$ ions each. Overall, the results demonstrate that PGT-based range monitoring remains viable for carbon-ion beams, although increased background from secondary protons indicates that detector configuration adaptations are required.

physics.med-ph↗

A simplified reconstruction of Positron Emission Tomography image using Time of Flight simulated data in Gate 10

Background: Ultrafast Time-of-Flight (TOF) information in Gate 10 simulations enables direct 3D PET reconstruction without scanner-specific modeling. Although such picosecond timing is not achievable in current detectors, simulated data allow exploration of idealized TOF regimes and rapid evaluation of prototype PET designs. Methods: The TOF-driven reconstruction assigns each coincidence to its annihilation position using sub-picosecond timestamps, producing voxelized 3D histograms with flexible voxel size and field-of-view selection. The approach operates directly on Gate-sorted coincidences, requires no corrections, and outputs MHD/DICOM images. Timestamp precision (~10^-13 s) enables localization on the millimeter scale. Results: Full 3D images of the simulated INSPIRE PET scanner are generated in under one second. The method resolves 0.25 mm features in point-source studies and 1.2 mm rods in the Derenzo phantom, reproduces ground-truth activity distributions in image-quality tests, and maintains quantitative stability across geometries. Performance reflects the theoretical benefits of ultrafast TOF rather than current detector capabilities. Significance: This fast, geometry-agnostic reconstruction tool supports early-stage PET prototyping, allowing rapid assessment of spatial resolution, sensitivity, and uniformity without implementing complex reconstruction software. It is broadly applicable to any simulated PET system with sorted coincidences and enables systematic exploration of ultrafast TOF performance in a controlled environment.

physics.med-ph↗