Search arXiv⌕ Search

arXiv · 2609.36339

Bridging cone-beam CT and MRI to stopping power ratio maps: a modality-agnostic Brownian bridge approach to support robust adaptive proton therapy

Abstract

Purpose: Adaptive proton therapy (APT) relies on routine offline CT simulations for updated anatomy. We present a modality-agnostic regularized Brownian bridge (rBBrg) framework to deterministically predict stopping power ratio (SPR) maps from CBCTs or MRIs. Methods: rBBrg consisted of (1) generation mapping where a Brownian bridge predicted SPR from input and (2) reconstruction mapping where a cGAN reconstructed input from predicted SPR. Class embedding was adopted for modality conditioning. Efficient, deterministic prediction was achieved via one-step sampling. Unimodality rBBrg and ResNet were implemented for comparison. Matched-pair planning CT-CBCT (n=37) and CT-MRI (n=21) from head-and-neck cancer patients were evaluated. A calibration phantom was scanned to establish Hounsfield look-up table for real SPR. Predicted SPR maps were evaluated via mean absolute error (MAE), peak-signal-to-noise ratio and structural similarity against ground truth with demonstration of dosimetric performance. Results: For CBCT-SPR synthesis, most metrics were comparable across models (p>=0.05). Modality-agnostic rBBrg outperformed ResNet in MAEbone (0.059 vs 0.067, difference=11%, p<0.05) and showed lower MAEexternal than ResNet (0.038 vs 0.040, p=0.05). Modality-agnostic and unimodality rBBrg were comparable (p>0.05). Qualitatively, both rBBrg better preserved anatomical fidelity than ResNet. For MRI-SPR synthesis, performance was overall comparable across models (p>0.05). Modality-agnostic rBBrg obtained MAEexternal=0.057. Dose calculation comparisons between real and CBCT-predicted SPR were higher in modality-agnostic rBBrg predictions compared to ResNet with gamma pass rate=98.8%/99.3% vs 94.5%/96.9% at 2 mm/2%, respectively. Conclusion: A novel modality-agnostic rBBrg model was developed to generate high fidelity, deterministic SPR from CBCT or MRI to support efficient and flexible APT workflow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yuhao Yan, Qisheng He, Minglei Kang, Behzad Hejrati, Christian Hyde, Ming Dong, Carri Glide-Hurst. 2026-09-28. Bridging cone-beam CT and MRI to stopping power ratio maps: a modality-agnostic Brownian bridge approach to support robust adaptive proton therapy. https://arxiv.org/abs/2609.36339

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

BART Online Open-Source Sequence Toolbox for Computational MRI

Purpose In advanced computational MRI techniques, acquisition and reconstruction techniques are jointly designed. For reproducibility, it is therefore important to provide an open implementation of both. At the same time, any use in a clinical environment usually requires a close integration with the MRI scanner. Ensuring long-time reproducibility and maintenance then poses additional challenges. In this work, we aim to provide a fully integrated open-source framework that can meet these demands. Methods A software framework to develop pulse sequences is added to BART, an open-source toolbox for computational MRI. In addition, a vendor-specific driver sequence is developed that can be used to run the sequence on a clinical MRI scanner enabling online adjustment of all relevant sequence parameters. Using the Pulseq format, the exact same sequence can also be reproduced offline using a widely used vendor-neutral open-source standard. Using the Pulseq format, the exact same sequence can also be reproduced offline. As proof-of-concept, quantitative MRI methods for T1 and joint water/fat R2*, B0 mapping using radial FLASH and model-based reconstruction are implemented in the proposed framework. Consistency between online and offline acquisition is validated in phantom and in vivo experiments. Results Quantitative MRI methods highlighting specific challenges of acquisition and reconstruction were successfully implemented in BART. Acquisition parameters and FOV can be adapted online on a clinical MRI system. Quantitative parameter maps from model-based reconstruction agree for online and offline regenerated Pulseq acquisitions. Conclusion This work enables reproducibility of advanced computational MRI methods within a comprehensive end-to-end open-source framework.

physics.med-ph↗

Quantifying the Impact of Upright Patient Positioning on Cardiac Substructures Using Deep Learning

Upright patient positioners with diagnostic-quality vertical CT at treatment isocenter may improve image-guided radiation therapy (RT). However, cardiac substructure (CS) geometry in upright patients remains insufficiently characterized. This work evaluated if a supine-trained deep-learning (DL) CS segmentation model generalizes to upright CT images and quantified posture-dependent CS changes in thoracic patients, to assess potential CS-sparing benefits. 8 thoracic proton therapy patients underwent paired supine/upright 4DCT imaging. 20 CS and lungs were manually labeled on both datasets for positional comparisons. A previously developed supine-trained, DL pipeline generated the same CS, and performance was evaluated using Dice similarity coefficient (DSC) and 95% Hausdorff distance (HD95). Upright CTs were rigidly registered to corresponding supine CTs by aligning the thoracic vertebrae, and CS centroid shifts were measured in the registered coordinate frame and relative to the carina. Paired differences were assessed using Wilcoxon signed-rank tests (p<0.05). The DL model successfully predicted all 20 CS on both upright (DSC, 0.65(0.24); HD95, 7.6(5.6)mm) and supine (DSC, 0.72(0.19); HD95, 5.8(2.6)mm) images yet with lower (p<0.05) performance upright. Upright positioning significantly increased median lung volume by 20.6% (range, -8.9%-42.8%). After vertebral alignment, most CS centroids shifted significantly inferior (median heart shift, 23mm; range, 18-37mm) and anterior (median heart shift, 5.0mm; range, 1.0-13.0mm) when upright. Relative to the carina, most CS shifted significantly inferior and closer anterior-posterior. A supine-trained DL model generalized to upright CT images for CS segmentation. Upright positioning produced increased lung volumes and significant inferior CS displacement, suggesting favorable geometry changes that may support cardiac-sparing workflows.

physics.med-ph↗

Using a radiopharmaceutical production cyclotron for radiobiological research

The Laboratory for High Energy Physics and the Institute of Anatomy at the University of Bern are establishing a pre-clinical proton therapy research facility at the Bern University Hospital (Inselspital). The facility centers on the Bern Medical Cyclotron, an 18 MeV compact cyclotron designed for microampere-range beam currents for radioisotope production. The Bern Medical Cyclotron can be adapted as a highly accessible and customizable platform for pre-clinical proton therapy research, enabling advanced modalities such as ultra-high dose rate (FLASH) radiotherapy and spatially fractionated radiation therapy. Human keratinocytes (HaCaT) and mouse melanoma (B16-F10) cell lines were irradiated with 8.14(29) MeV protons at conventional dose rates and with 225 kV X-rays at doses from 0 to 8 Gy. Clonogenic survival assays were analyzed using the linear-quadratic model, and relative biological effectiveness values were derived by comparing the proton and X-ray doses required for 0.1 survival. Proton irradiation yielded steeper survival curves than X-rays, indicating higher cytotoxicity. B16-F10 cells were most sensitive, with a relative biological effectiveness of 1.34 at 0.1 survival, while HaCaT cells showed a relative biological effectiveness of 1.21. These results confirm enhanced proton effectiveness in cell killing and demonstrate that the Bern Medical Cyclotron provides a reliable platform for radiobiological studies. Establishing in vitro proton irradiation capability marks a key milestone toward developing a comprehensive pre-clinical radiobiology research facility in Bern. Ongoing upgrades will further refine dosimetry and proton delivery, paving the way for future FLASH and proton spatially fractionated radiation therapy studies.

physics.med-ph↗