A Guidewire Trajectory Generation Tool for Interventional MRI Simulations

Abstract

Significance: RF-induced heating of endovascular devices limits MRI-guided interventions, including targeted drug delivery to brain tumors. Purpose: To present a tool that rapidly generates randomized guidewire trajectories for RF heating risk assessment. Methods: A MATLAB tool models the guidewire as a spline with randomized control nodes and a fixed nominal length. As a use case, tip sSAR was estimated for 1000 trajectories using straight-wire transfer functions and 64 MHz local and body coil fields (matched B1) in the Duke phantom. Results: Length accuracy was 99.84%, and 3000 trajectories were generated in 11.5 s. Body-to-local sSAR ratios at the 50th, 95th, and 99th percentiles were 1.5, 1.6, and 2.27, but some trajectories heated more under the local coil. Conclusion: The tool enables large-sample heating assessment, and coil type alone did not reliably predict individual trajectory risk.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fatima Ben Haj, Jeffrey Hand, Shaihan Malik, Felipe Godinez. 2026-10-03. A Guidewire Trajectory Generation Tool for Interventional MRI Simulations. https://arxiv.org/abs/2610.04216

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Radiation damage to normal mammalian tissue in vivo with laser-driven protons at ultra-high instantaneous dose rate

The differential sparing of normal tissues relative to tumor control observed at ultra-high dose rates, referred to as the FLASH effect, has recently gained considerable attention. The therapeutic advantages of FLASH radiotherapy are expected to be further amplified through the use of protons and ions, which enable precise dose deposition at tumor depth while minimizing irradiation of healthy tissues proximal and distal to the target. Nevertheless, the mechanism underlying this sparing effect remains poorly understood. Laser-driven proton accelerators are capable of delivering uniquely high instantaneous dose rates in ultrashort bunches. Here, we report the first in vivo investigation of normal tissue response to laser-driven proton irradiation, with exposures to 8 MeV protons, delivering total doses up to 50 Gy at 2 Gy per laser shot. Our findings reveal a reduction in tissue swelling following laser-driven proton treatment compared with X-ray irradiations at conventional dose rates. RNA sequencing identified differential gene expression associated with immune and epidermal programs following laser-driven proton irradiations at two different dose levels.

physics.med-ph↗

Edge-Aligned Beam Placement in Scanning Probe Tomography via Reconstruction-Free Sequential Design of Experiments

In X-ray scanning probe tomography, reconstruction quality generally improves with larger numbers of projections. However, additional projections increase experiment costs, acquisition time, and the radiation dose imparted to the sample. One mitigation to these trade-offs is to adopt a sequential design of experiments, in which each subsequent measurement is determined as a function of previously acquired data in order to maximize information gain. In scanning probe tomography, a widely used heuristic to maximize information is to align beams with the edges of the sample. A key challenge, however, is that the true sample is unknown, so identifying edge-aligned beams typically requires reconstructing the sample based on available measurements. This work proposes a novel sequential design method that identifies edge-aligned measurements directly from the sinogram, bypassing any reconstruction, thereby improving computational efficiency and reducing the experimental design's susceptibility to reconstruction errors. Our method dynamically selects the next set of measurement beams by maximizing an acquisition function that balances exploration and exploitation over the domain of all possible measurements, improving reconstruction quality while reducing measurement redundancy.

physics.med-ph↗

Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms

Conservative dose remapping can be formulated by transporting mass and deposited energy across nonmatching grids, but fixed sampling uses the same number of points per active source cell regardless of case difficulty. We developed conformal multiresolution error control (CoMERC), a fail-closed multilevel quasi-Monte Carlo (QMC) controller for reference-relative target-cell allocation error in a fixed piecewise-constant source model with known deformation. Two randomized nested replicates were evaluated at a probe level of 4 and candidate levels of 8 and 16. Four endpoints were controlled jointly: reference-mass-weighted global, high-gradient, and density-gradient-threshold root-mean-square error, plus eligible-cell maximum absolute error. A split-conformal multiplier was calibrated from 240 synthetic cases, frozen, and evaluated on 400 independent cases from the same generator and 120 cases from a prespecified shifted generator. In the primary set, joint coverage was 394/400 (98.50%; one-sided 95% lower limit, 97.06%), 388/400 cases (97.00%; lower limit, 95.18%) received an output, and 0/388 released outputs exceeded any tolerance (one-sided 95% upper limit, 0.769%). Final actions were level 8 for 190 cases, level 16 for 198, and ABSTAIN for 12. The mean of the case-normalized, policy-implied production-sample ratios was 0.5844, with each case normalized to always running both randomized replicates through level 16; the prespecified 95th-percentile bootstrap upper limit was 0.6194. All seven primary gates passed. In the shifted-generator set, 113/120 cases were released and one released output exceeded a tolerance. CoMERC provided marginal finite-sample error control and lower modeled production-sample work in the locked synthetic population, but not patient-level, registration-level, conditional-on-release, or clinical safety validation.

physics.med-ph↗