A software tool for parametric collimator creation for linac-based preclinical irradiation studies

Abstract

Designing custom Cerrobend collimators for linac-based preclinical electron irradiation is labor intensive and susceptible to design inconsistencies. We developed Collimator Creator (CC), an open source parametric workflow that converts aperture dimensions and jig offsets into printable STL models for a collimator mold, collimator shell, Cerrobend holder, and beam degrader. Two designs were fabricated and characterized: a 4.0 x 1.5 cm$^2$ bilateral lung collimator centered on the central axis and a 1.5 x 1.5 cm$^2$ unilateral lung collimator with a 7.5 mm jig offset, each with a 15 mm thick Cerrobend collimator and a 10 mm PLA degrader. Kilovoltage planar images were used to assess aperture geometry and casting uniformity. Radiochromic film was used to measure full width at half maximum (FWHM) and 80%-20% penumbra under conventional and ultra high dose rate (UHDR) electron delivery on a Varian TrueBeam, and off axis leakage was measured with an ionization chamber at conventional dose rate. The cast Cerrobend apertures deviated by less than 0.2 mm from their specified designs. FWHM values were within 3% of the nominal field dimensions, and penumbra ranged from 0.73 to 1.05 mm under conventional and UHDR delivery. Crossline leakage 2 cm beyond the collimator edge was below 2% for both collimators at conventional dose rate. Parametric collimator generation standardized digital design inputs for the two evaluated rectangular linac-based electron fields. Further work will assess specimen-level dosimetry, additional aperture geometries, and Monte Carlo integration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Joseph B. Schulz, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi, M. Ramish Ashraf, Lawrie Skinner, Edward Elliot Graves, Billy W. Loo Jr, Stavros Melemenidis. 2026-10-05. A software tool for parametric collimator creation for linac-based preclinical irradiation studies. https://arxiv.org/abs/2610.06457

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

APHABAMAS: An analytical phantom-based scheme for assessing the accuracy of high-resolution 3D MRI motion-artifact simulations

Purpose: Motion compromises the utility of high-resolution 3D MRI, an established tool in quantitative neuroimaging research. Deep learning-based methods have shown promise for mitigating motion-induced artifacts, but their development typically requires simulated motion-corrupted data. Several open-source tools exist for this task, each implementing different algorithms. However, no scheme currently exists for evaluating the accuracy of these simulations, making it difficult for users to choose the most suitable tool. This study aims to develop such a scheme. Methods: The essential ingredient of the desired scheme is a ground-truth reference that does not suffer from sampling-induced error. To meet this requirement, the proposed scheme, APHABAMAS, leverages a digital phantom whose image- and Fourier-domain representations can be expressed analytically under arbitrary rigid-body transformations. APHABAMAS is used to quantify sampling-induced errors of three existing algorithms under synthetic and tracking-data-derived motion trajectories at different motion severity levels. Results: All three algorithms produce distinct but visually plausible artifacts, demonstrating the need for a ground-truth reference. APHABAMAS shows that the algorithm utilizing the uniform-to-non-uniform (Type-2) NUFFT provides the most consistent agreement with the ground-truth reference across motion types and severity levels. The non-uniform-to-uniform (Type-1) NUFFT-based algorithm, which does not mimic the MR acquisition process, deteriorates substantially with increasing motion severity. Conclusions: APHABAMAS provides a rigorous tool for assessing the accuracy of high-resolution 3D MRI motion-artifact simulations. It enables accuracy-based assessment of three existing algorithms, thereby facilitating informed selection of the most suitable one for synthesizing motion-corrupted data.

physics.med-ph↗

The FetalSenseM V2: a wearable and wireless, multi-wavelength NIRS device for continuous monitoring of placental oxygenation and metabolism

We present here the FetalSenseM V2 (FSM V2), a wireless and wearable, multi-wavelength, NIRS device, based on LED illumination at six NIR wavelengths (782, 800, 818, 830, 848 and 888 nm). It utilises two sources located on the flexible wings of the sensor body, and three photodiodes placed symmetrically in its centre at 1 cm from each other. The configuration provides two sets of three source-to-detector distances (SDS) at 3, 4 and 5 cm. FSM V2 allows estimation of dynamic, relative changes in placental concentrations of HbO2, HHb and oxCCO. At the same time, the dual set of SDS also enables the use of multi-distance algorithms, such as spatially-resolved spectroscopy (SRS) and Dual Slope (DS), for estimating placental oxygen saturation (PlO2). FSM V2 is the first example of a new generation of wearable NIRS devices, paving the way for smart and advanced monitoring of placental health at bedside. The FSM V2 was successfully validated on a bench-testing, metrological platform based on optical phantoms, as well as against a gold-standard, time-domain (TD) NIRS system, before moving to preliminary examples of clinical application and usability on pregnancy monitoring trials at University College Lon-don Hospital (UCLH), conducted as part of an in vivo proof-of-concept study.

physics.med-ph↗

A Differentiable Brain Tumor Mass Effect Solver

A growing brain tumor mechanically deforms the surrounding healthy brain through mass effect. This compression and displacement of tissue affects both patient prognosis and treatment planning, so biophysical models of tumor growth must account for this deformation. Established mass-effect models are partial differential equation (PDE) solvers that couple growth to elasticity and calibrate parameters per patient, at substantial implementation, runtime, and calibration cost. We ask how much of this deformation a fully differentiable energy-based model can recover, and introduce a potential-spring model: a regular grid over the brain is driven outward by a tumor-concentration potential and held by an elastic spring lattice with tissue-specific stiffness. It shares the tumor-gradient driving force of continuum elasticity but uses a single global parameter and no per-patient inversion, minimized end-to-end by gradient descent. We benchmark it against established solvers by applying each displacement field to a healthy atlas and measuring tissue overlap with the patient's own segmentation on 134 BraTS patients. Our model yields the largest overall local overlap improvement at up to 100$\times$ shorter computation time, establishing a lightweight, differentiable solver for tumor mass effect. Because our model obeys mechanical laws and reflects the tumor-induced tissue loading, it remains physically plausible, a prerequisite for clinical use.

physics.med-ph↗