Search arXiv⌕ Search

arXiv · 2610.06500

Polyurethane Scintillators for High-Energy Physics Detectors: Optimization, Scale-up, and Radiation Response

Abstract

Plastic scintillators remain attractive for large-area particle detectors because of their fast response, mechanical flexibility, and relatively simple fabrication. Motivated by future applications including the ALICE~3 Muon Identifier (MID) and the upgrade of the ALICE Fast Interaction Trigger (FIT), this work investigates polyurethane (PU)-based plastic scintillators doped with 2,5-diphenyloxazole (PPO) and 1,4-bis(5-phenyloxazol-2-yl)benzene (POPOP). Systematic information on the optimization and radiation response of this material system remains limited. A series of compositions was therefore fabricated and characterized using minimum-ionizing particles (MIP), optical spectroscopy, and time-correlated single-photon counting. The measurements show that the scintillation response is governed primarily by the PPO concentration, while POPOP mainly modifies the spectral response, and fast effective decay times of approximately 1.6--1.75~ns are maintained across the doped samples. The best-performing formulation was subsequently scaled to 20-$cm$ and 1-m scintillator bars and successfully operated with a single embedded wavelength-shifting fiber and SiPM readout, demonstrating its suitability for meter-scale light collection. Proton-irradiation measurements at the CERN IRRAD facility further revealed systematic degradation of the optical and scintillation responses with increasing exposure, together with substantial recovery after approximately two months. These results demonstrate that optimized PU--PPO--POPOP scintillators can combine fast timing, high light output, scalable detector geometry, and recoverable radiation response, supporting their further development for future large-area particle-detector systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rafael Angel Narcio Laveaga, Ildefonso León Monzón, Juan Carlos Cabanillas Noris, Thanh Luan Nguyen, Jan Král, Vítezslav Jarýd, Gerardo Herrera Corral, Vojtech Zabloudil, Etiennette Auffray, Carlos Duarte Galván, Solangel Rojas Torres. 2026-10-05. Polyurethane Scintillators for High-Energy Physics Detectors: Optimization, Scale-up, and Radiation Response. https://arxiv.org/abs/2610.06500

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Projection of purification performance for the RELICS experiment

The RELICS (REactor neutrino LIquid xenon Coherent elastic Scattering) experiment employs a dual-phase liquid xenon time projection chamber to search for Coherent Elastic Neutrino-Nucleus Scattering (CE$ν$NS) induced by reactor neutrinos. To detect these sub-keV nuclear recoils and minimize signal attenuation, it is critical to maintain a sufficiently low impurity concentration in the detector. This work presents a comprehensive purity evolution model developed to describe impurity migration inside the detector. Utilizing measured material outgassing rates as input parameters, the model incorporates non-uniform transport mechanisms of the impurities, including circulation, vaporization, and condensation. The model is validated using data from a dedicated prototype detector. Based on this validated model, projections for the purification performance of the upcoming RELICS-10 and RELICS-50 detectors are provided.

physics.ins-det↗

Energy, time, and position resolution measurements of an array of large tapered LYSO crystals

We report on the performance of six custom-made tapered LYSO crystals of unprecedented volume, which constitute a sector of the 19 radiation length electromagnetic calorimeter planned for the PIONEER experiment. The longitudinal response uniformity of each crystal was measured using radioactive sources before characterizing the energy and time resolution of the crystals in an array using a 20 to 80 MeV positron beam at the Paul Scherrer Institute. The array demonstrated an energy resolution better than 2 % for energies above 40 MeV and a time resolution better than 140 ps for energies above 30 MeV. The spatial resolution was measured in the central region of the array to be 5.06 mm in x and 5.20 mm in y at 70 MeV. The measured properties satisfy the key design parameters of the PIONEER calorimeter for the measurement of rare pion decays.

physics.ins-det↗

Investigating Optical Coupling Material Candidates in NaI(Tl) Detectors for the SABRE-North Dark Matter Experiment

Direct dark matter detection with NaI(Tl) scintillators requires ultra-low-background materials. Silicone optical pads can couple NaI(Tl) crystals to photomultiplier tubes (PMTs) if they provide adequate optical transmission and radiopurity. We characterize four candidate materials for the SABRE-North experiment: commercial EJ-560, used as a reference, and three materials produced at the University of Salento (SYLGARD 184, EGel 3002 A/B, and a hybrid formulation) using different catalyst ratios and curing conditions, yielding ten samples in total. Optical transmittance was measured from 310 to 850 nm by UV/Vis/NIR spectrophotometry. Radiopurity was assessed at the STELLA facility at LNGS using high-purity germanium (HPGe) $γ$-ray spectrometry and, for EJ-560, high-resolution ICP-MS. At the 410 nm NaI(Tl) emission peak, EJ-560 shows an absorbance coefficient of $0.064\pm0.017$ mm$^{-1}$. The best locally produced samples reach $0.097\pm0.015$ and $0.093\pm0.014$ mm$^{-1}$ for SYLGARD 184 with a 10:2 base-to-catalyst ratio cured at room temperature and at $40^\circ$C, respectively, $0.125\pm0.015$ mm$^{-1}$ for EGel 3002 with a 2B:A ratio cured at $40^\circ$C, and $0.106\pm0.014$ mm$^{-1}$ for the hybrid 10:1 EGel A:CataSYL formulation cured at room temperature. EJ-560 exhibits detectable $^{232}$Th-chain activity at about 1.8 mBq/kg and the highest $^{40}$K activity, $(120\pm20)$ mBq/kg. The locally produced materials show no detectable Th-chain contamination but exhibit $^{226}$Ra activities of about 2.3 mBq/kg and lower $^{40}$K levels. No single material is optimal across all criteria. Additional ICP-MS screening, HPGe measurements of cured pads, and direct NaI(Tl)-PMT light-yield tests are required for a conclusive SABRE-North material selection.

physics.ins-det↗