Search arXiv⌕ Search

arXiv · 2610.06566

Digital confocal imaging in holographic optical coherence tomography at high space-bandwidth product

Abstract

Full-field Fourier-domain optical coherence tomography (FF-FD-OCT) enables rapid volumetric imaging but lacks the confocal gating inherent to point-scanning OCT. By acquiring volumes under multiple oblique illuminations, a digital confocal volume can be synthesized in post-processing, a technique originally developed within the framework of reflection matrix imaging (RMI). Existing implementations, however, are often time-domain, off-axis, or use a Michelson interferometer, which reduces sensitivity, speed and the usable space-bandwidth product (SBP). Here, we present an oblique-illumination FF-FD-OCT system in a Mach-Zehnder configuration. This setup enables optimal use of SBP, providing up to a fourfold increase in effective acquisition throughput. In addition, we pose the scattering and aberrations as an overdetermined system, allowing a closed-form solution of an alternating least squares problem. The resulting iterative optimization is equivalent to the state-of-the-art closed-loop accumulation of single scattering (CLASS) algorithm. We demonstrate the setup and reconstruction method in lens tissue, a PSF phantom, a USAF target, and a model eye. The resulting digital confocal volumes provide locally optimized focusing and detection quality, and show improved resolution and signal-to-noise ratio (SNR) compared to conventional FF-FD-OCT. The technique combines the advantages of FF-FD-OCT and confocal OCT while mitigating the limitations of both approaches.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N. P. Klooster, S. A. Thakur, F. Zeisberger, J. R. Hagen, S. Eggert, U. Najar, D. Hillmann. 2026-10-05. Digital confocal imaging in holographic optical coherence tomography at high space-bandwidth product. https://arxiv.org/abs/2610.06566

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Vectorial Control of Scintillation in Kolmogorov Turbulence and Quality Parametrization

Intensity scintillation limits free-space optical links in strong turbulence. We examine experimentally how sequential linear polarization filtering modifies the scintillation of a laser beam distorted by Kolmogorov-type turbulence, and interpret the results with a vector-field and fourth-order-moment model. A collimated He--Ne beam (632.8~nm) crossed a rotating pseudo-random phase plate (Fried parameter $r_0\approx0.6$~mm) and zero to five co-aligned thin-film polarizers; 200 camera frames were recorded per configuration, together with a turbulence-free reference. For fully developed speckle the model gives a total-field index $σ_I^2=(1+P^2)/2$ in terms of the degree of polarization $P$. From zero to five polarizers, the Gaussian-envelope scintillation index fell from 0.083 to 0.002 and the single-pixel index from 0.80 to 0.27 (about 66\%), whereas beam wander remained comparable across configurations. As Gaussian statistics alone cannot explain this reduction, we attribute it to rejection of a depolarized, strongly fluctuating component and derive a quantitative criterion for this mechanism. Passive polarization filtering thus offers a simple, low-cost route to scintillation mitigation in free-space optical terminals.

physics.optics↗

Constraints on the Origin of Universal $1/f^2$ Photon-Count Spectra at Baseband

A series of 11.6-d-duration photon-counting experiments, employing a broad variety of light sources with different statistical properties and optical spectra, were carried out over a 1.5-yr period. All of the photon-count spectra at baseband followed a common $1/f^2$ form over the frequency range $1 \times 10^{-6} \leqslant f \leqslant 5 \times 10^{-4}$ Hz, corresponding to a timescale range $33$ min $ \leqslant T_f \leqslant 11.6$ d, where $T_f \equiv 1/f$. The lower and upper timescale limits were established by the photodetector noise floor and the duration of the individual experiments, respectively. Unlike ordinary Brownian motion, all of the measured photon-count sample paths exhibited irregular long-timescale fluctuations, with durations ranging from hours to days. It has been established that the photon-count spectra cannot plausibly be ascribed to fluctuations of the current, voltage, or temperature of the source or the detector, nor to technical sources of noise associated with the optical system or local environment. Although the physical origin of the photon-count fluctuations remains unresolved, several heterodox hypotheses are set forth. From a statistical point-of-view, the photon counts appear to follow a doubly stochastic Poisson process with a slowly varying random intensity. Analogous experiments that rely on ionizing radiation and direct-conversion solid-state radiation detectors are proposed.

physics.optics↗

Scatter-free perfect reflection in multichannel monolithic high-contrast gratings: direct--indirect Fourier-harmonic interference and dimensionality of the solution set

Monolithic high-contrast gratings (MHCGs) can exhibit scatter-free perfect reflection despite open higher-order substrate diffraction channels, but the underlying mechanism has not been fully clarified. Using a Fourier-harmonic description, we show that all open higher-order channels in the high-index substrate can be simultaneously extinguished through destructive interference between the radiation fields generated by the direct and indirect source contributions. By contrast, the zeroth-order transmission vanishes when the modulation-induced zeroth-order field interferes destructively with the background transmitted field of the incident wave. Together, these cancellations yield unit zeroth-order reflectance in lossless MHCGs. The near invariance of the internal field harmonics accounts for the remarkable stability of these conditions against changes in the substrate refractive index. We further show that the number of symmetry-compatible open channels determines the generic codimension of the perfect-reflection solution set. Depending on the number of independent design parameters relative to this codimension, the solutions form continuous curves, appear as isolated points, or are generically absent. Introducing an additional geometrical parameter restores isolated perfect-reflection solutions when an additional diffraction channel opens. The same cancellation mechanisms and channel counting apply to both TE and TM polarizations.

physics.optics↗