In-flight Timing Calibration of the Follow-up X-Ray Telescope on Board the Einstein Probe

Abstract

After the launch of Einstein Probe (EP), pulsars are observed to calibrate the timing system of the onboard Follow-up X-ray Telescope (FXT) by measuring the times of arrival (TOAs). FXT has two independently operating modules, namely FXTA and FXTB, each equipped with the Wolter-I optics and the pnCCD camera. For scientific observations, each pnCCD has three distinct readout modes that differ in frame cycles, the full frame mode (FF, 50 ms per frame), the partial windowed mode (PW, 2.2 ms per frame), and the timing mode (TM, 23.68 $μ$s per row, 9.4352 ms per frame). Thus, 1RXS J170849.0--400910 with the spin period of 11 s is observed in FF, PSR B1509--58 (150 ms) in PW, and Crab pulsar (33 ms) in TM as well as PSR B1821--24 (3.05 ms) and PSR B1937+21 (1.56 ms). The TOAs of these pulsars measured by FXTA and FXTB are compared with the results of NICER, and for Crab pulsar with the Jodrell Bank Monthly Ephemeris (JBE). Results verify that the timing system of FXTA and FXTB in FF, PW, and TM modes are consistent with each other, and are in good alignment with NICER. The measured advance of the Crab pulsar's main peak relative to JBE is $357^{\pm14(stat)}_{\pm54(sys)} μ$s in FXTA and $394^{\pm14(stat)}_{\pm67(sys)} μ$s in FXTB. Based on measurements of PSR B1821--24 and PSR B1937+21, the preliminary absolute timing accuracy is estimated to be 6 $μ$s for FXTA and 31 $μ$s for FXTB in TM mode. Additionally, the systematic delay of FXTA timing results relative to FXTB is found to be $20^{\pm19(stat)}_{\pm21(sys)} μ$s.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Juan Zhang, Xiaofan Zhao, Dawei Han, Hao Wang, Yong Chen, Mingyu Ge, Shijie Zheng, Shumei Jia, Haisheng Zhao, Weiwei Cui, Hanlong Peng, Wentao Ye, Yaoming Duan, Youli Tuo, Zhen Ji, Fuli Ma, Chengkui Li, Ju Guan, Jingjing Xu, Jin Wang, Liming Song. 2026-10-09. In-flight Timing Calibration of the Follow-up X-Ray Telescope on Board the Einstein Probe. https://doi.org/10.3847/1538-4365%2Fae60f8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Validation of Satellite Lifetime Predictions at Leonid Space

This paper validates Leonid Space's satellite lifetime prediction pipeline through a backtesting campaign of 878 deorbited satellites spanning six decades of spaceflight, showing that it accurately recreates their last year of flight. The pipeline combines a custom high-speed orbit propagator, ballistic coefficient estimation from on-orbit TLE data, atmospheric density corrections from data assimilation, custom space weather forecasts, and probabilistic Monte Carlo analysis. Validation proceeds in four steps that progressively remove the benefit of hindsight: starting from a "perfect knowledge" scenario using actual space weather data and ephemerides, we gradually replace historical data with contemporary predictions to arrive at a fully predictive scenario analogous to a deorbit prediction performed for a spacecraft flying today. These forecasts are scored using the continuously ranked probability score and root mean square calibration error, yielding a median one-year prediction accuracy of 3.9 days (1.1%) with perfect knowledge and 44.9 days (12.3%) in the fully predictive scenario. Solar flux forecasts contribute 89% of the variance in our predictions, dominating all other sources of error. To our knowledge, this is the first comprehensive backtesting of long-term satellite lifetime predictions that reports quantitative results for the fully predictive case, and it establishes a new framework for scoring solar cycle forecasts by grounding forecast accuracy in operationally-relevant satellite lifetime predictions.

astro-ph.IM↗

CHRONOS Science Program

Cryogenic sub-Hz cROss torsion-bar detector with quantum NOn-demolition Speed meter (CHRONOS) is a proposed cryogenic torsion-bar interferometer for precision measurements in the 0.1-10 Hz band. A Sagnac speed-meter readout, power and signal recycling, and balanced homodyne detection provide control of the optical response and quantum measurement correlations. This White Paper describes the science program, detector design, calibration, and staged experimental development. The reference sensitivity uses a multi-input quantum model, including rear-mirror vacuum fields and measurement-back-action correlations, combined with classical noise. Two operating points are optimized for complementary power-law-integrated sensitivity objectives. Gravitational-wave forecasts use this common noise budget and state their source and observing assumptions. The program includes intermediate-mass black-hole binaries, stochastic backgrounds, quantum measurement, and terrestrial gravity perturbations. Dark-matter applications are discussed as response and feasibility studies. A differential gravitational calibrator provides a proposed Yukawa-gravity test whose systematic floor is improved by subtracting auxiliary harmonics. These are conditional projections: experimental reach requires validation of the noise, transfer functions, environmental backgrounds, and systematic uncertainties described here.

astro-ph.IM↗

pynucastro 3: A community library for nuclear astrophysics

We describe the latest release of pynucastro: a community python library for nuclear astrophysics. The goal of the pynucastro project is to build the tools needed to interactively explore nuclear properties, reaction rates, and networks, and to export these networks to a variety of simulation codes. Major changes in pynucastro since the last major release include new rate approximations, a stellar equation of state, support for the StarLib library and rate uncertainties, and new tools for exploring networks.

astro-ph.IM↗