Search arXiv⌕ Search

arXiv · 2610.20132

A low-cost compact muon detector for millikelvin operation

Abstract

Ionizing radiation produces correlated errors in superconducting qubits, posing some challenges to quantum error correction. In addition, it causes background events in other superconducting cryogenic devices, such as kinetic inductance detectors and superconducting nanowire single-photon detectors. Cosmic muons are a component of this background that can only be partly shielded against at ground level, but can be tagged by an independent detector inside the cryostat, so that the affected data can be vetoed, or the muon tags incorporated into error correction. We present a low-cost, compact muon detector consisting of two plastic scintillator modules, each read out by a silicon photomultiplier (SiPM), operated in coincidence. We characterize the SiPMs from room temperature down to 10 mK, including the breakdown and upper-limit voltages that define the operating bias range. Operated as a muon counter, the detector measures a coincidence rate that, as expected, is independent of temperature within uncertainties and agrees with analytical and Monte Carlo predictions. Below approximately 8 K, each muon event produces two pulses, one narrow and one broad, an effect that, to our knowledge, has not been reported before. Coincidences with an independent muon detector outside the cryostat confirm that muons are still counted reliably in this regime. By studying the appearance of double pulses as a function of temperature and magnetic field up to 4.5 T, we find a behavior consistent with the phase diagram of a type-II superconductor. This links the double pulses to a superconducting material in the SiPM, likely an adhesion layer or diffusion barrier introduced during manufacturing. The mechanism by which the superconducting state produces the second pulse is not yet understood.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tengiz Ibrayev, Danish Khan, Alex Herscovics, Komal Kataruka, Matilda Lawton, Sandhya Sharma, Steven Waddy, Laura Manenti. 2026-10-14. A low-cost compact muon detector for millikelvin operation. https://arxiv.org/abs/2610.20132

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Physics at the Edge: Benchmarking Quantisation Techniques and the Edge TPU for Neutrino Interaction Recognition

This work presents a benchmark of quantisation techniques for convolutional neural networks applied to neutrino interaction recognition, motivated by the need for low-power inference close to the detector in future liquid argon time-projection chamber (LArTPC) experiments. Using simulation of a generic LArTPC, four Keras models are trained to classify neutral-current, muon-neutrino charged-current and electron-neutrino charged-current interactions, quantised using post-training integer quantisation and quantisation-aware training, and deployed on the Google Coral Edge TPU. Latency and energy per event are compared with those of an Intel Core i7-13650HX CPU, a consumer NVIDIA RTX 4060 GPU and a data-centre NVIDIA A100 GPU, using measured energy at different batch sizes and thread counts; the energy of the Edge TPU is estimated from its nominal power. The accuracy degradation is strongly model-dependent: InceptionV3 shows no significant loss along either pipeline, whereas the other models are substantially degraded. At batch size 1, the Edge TPU is comparable to or faster than the CPU and 1.3-6.5 times slower than the A100, while requiring 5--70 times less energy per event than the other devices; with batching, the GPUs reduce this gap to a factor of 2.6-7.2. The Edge TPU is also approximately four times cheaper than the consumer GPU and more than two orders of magnitude cheaper than the A100. Its low power per device eases deployment where power and cooling are constrained, with an additional benefit in terms of environmental impact. This paper explores possible future integrations of edge AI technologies with neutrino physics.

physics.ins-det↗

Scan-Coil Delay Causes Anisotropic Signal Loss in Fast 4D-STEM

Fast pixelated detectors are driving 4D-STEM toward microsecond dwell times, a regime in which the finite response of the scan deflection coils becomes comparable to the dwell time itself. Using direct probe imaging and sub-frame diffraction analysis, we document a significant intra-dwell scan-coil delay that systematically smears the recorded signal anisotropically along the fast scan direction, with a settling timescale of several tens of microseconds. We present a phase-correlation-based sub-frame alignment procedure that measures and corrects this smearing, and we assess its impact on focused and defocused 4D-STEM reconstructions over a range of scan step sizes. The correction restores signal across a broad range of spatial frequencies, with the largest gains at the large step sizes required for low-dose biological imaging. Because it operates on existing data with no modification to the microscope, the method offers a practical route to recovering signal that would otherwise be lost to scan-coil delay.

physics.ins-det↗

Development of high-resolution timing technique in the past 25 years

This paper reviews recent progress in high-resolution timing, rate capability, and aging performance of particle detectors in the context of developments over the past 25 years. It focuses on MCP, SiPM, LGAD, 3D silicon, and SiEM detectors and compares their performance with that of gaseous timing detectors. In addition, preliminary results from a simplified simulation program, Mini-TCAD, are presented, indicating that hexagonal 3D silicon cells may provide better drift-time uniformity and timing resolution than square cells.

physics.ins-det↗