Search arXiv⌕ Search

arXiv · 2610.20470

Reynolds-number-dependent entrance bias in temperature polarization of lab-scale membrane distillation

Abstract

Lab-scale membrane distillation (MD) modules are commonly used for membrane characterization and developing empirical heat-transfer correlations. Entrance-induced flow structures can introduce geometry-specific effects into measured temperature polarization (TP) and heat transfer. However, the dependence of these effects on module geometry and flow condition remains unclear. We performed three-dimensional computational fluid dynamics (CFD) simulations of direct contact membrane distillation (DCMD) over inlet Reynolds numbers of $\Re_{\mathrm{in}}=10$-$1000$, focusing on side-chamber length and main-channel height. We discovered that counter-rotating streamwise vortices formed near the main-channel entrance across all geometries, but their downstream persistence increased with $\Re_{\mathrm{in}}$. At lower $\Re_{\mathrm{in}}$, the vortices mostly decayed before mid-channel, while at higher $\Re_{\mathrm{in}}$ they persisted farther downstream and produced pronounced spatial variations in TP. Increasing side-chamber length reduced the secondary-flow kinetic energy entering the main channel, and generally strengthened TP, whereas increasing main-channel height reduced the bulk velocity and streamwise kinetic energy, resulting in a thicker thermal boundary layer and stronger TP. For most geometries, the deviation from the straight-channel baseline changed from stronger TP at lower $\Re_{\mathrm{in}}$ to weaker TP at higher $\Re_{\mathrm{in}}$. Entrance effects therefore vary in both magnitude and direction with operating condition and cannot be represented by a constant correction across the Reynolds-number range.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Soyoung Kim, Tiezheng Tong, Yinuo Noah Yao. 2026-10-14. Reynolds-number-dependent entrance bias in temperature polarization of lab-scale membrane distillation. https://arxiv.org/abs/2610.20470

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Linear causality and stability constraints on relativistic second-order magnetohydrodynamics

In this work, we construct a theoretical framework for relativistic second-order magnetohydrodynamics based on entropy current analysis. The formalism consistently incorporates finite relaxation dynamics of the dissipative fluxes, providing a transient framework suitable for analyzing linear stability and short-wavelength causality. Utilizing linear mode analysis, we investigate the constraints imposed by causality and stability on this anisotropic system. By linearizing the theory around a homogeneous equilibrium state, we identify the magnetosonic, Alfvén, and charge-diffusion sectors, together with their coupling terms. For each sector, we derive asymptotic dispersion relations in both the long-wavelength (small-$k$) and short-wavelength (large-$k$) regimes, validating them against exact numerical roots. Our numerical analysis confirms the accuracy of these asymptotic solutions and uncovers a nontrivial angular dependence, especially near special propagation directions where the ordinary momentum expansion becomes less reliable. By evaluating the large-$k$ behavior of the propagating branches alongside the damping properties of non-hydrodynamic modes, we delineate the corresponding causality constraints. We find that the admissible linear causal domain is governed by the interplay between propagation direction, anisotropic transport coefficients, and relaxation times, with the resulting bounds being intrinsically mode-dependent. These findings provide a systematic theoretical basis for investigating linear stability and short-wavelength causality in relativistic magnetohydrodynamics beyond the first-order approximation.

physics.flu-dyn↗

An Omni-Temporal Framework for Hydrodynamic Dispersion and Reaction in Porous Media

Many applications involve porous-media transport driven on time scales comparable to the pore-scale diffusion time, for which classical pseudo-steady dispersion models based on time-invariant transport coefficients may become inaccurate. While frequency-dependent dispersion has been studied in non-reactive porous media, a corresponding framework that simultaneously accounts for advection, diffusion, and heterogeneous interfacial reaction remains lacking. We address this gap by introducing an omni-temporal framework based on volume averaging of the frequency-domain pore-scale advection-diffusion equation subject to a Robin boundary condition spanning the full range of interfacial reactivity. The resulting upscaled formulation yields four frequency-dependent transfer functions: a dispersion tensor, an advection-suppression vector, a spectral Sherwood number, and a reactivity-bias vector, with the reactivity-bias vector introduced here for the first time. Analytical solutions for fully developed flow between parallel plates and through circular tubes reveal distinct kinetics- and diffusion-limited regimes, including capacitive and semi-infinite Warburg-type frequency responses. Comparisons of transient breakthrough curves with direct numerical simulations demonstrate substantial improvement over conventional pseudo-steady dispersion, particularly for short-duration pulses. Application to a periodic array of square rods under cross flow further demonstrates the frameworks applicability beyond canonical geometries.

physics.flu-dyn↗

Comparative Numerical Study of Film Cooling Strategies for Thermal Protection of a Kerosene-Fueled Oblique Detonation Combustor

Thermal protection remains a major challenge for oblique detonation engines (ODEs), whose combustors combine intense heat release, anchored on oblique detonation waves (ODWs). This study numerically investigates the effects of coolant type and mass flow rate on the flow structure, thermal environment and propulsion performance of a film-cooled kerosene-air ODE combustor at Mach 10 and 15 km altitude. Three active cooling strategies are compared under identical conditions: air film cooling, gaseous-kerosene film cooling, and liquid-kerosene mist cooling. Stable, wall-attached oblique-detonation propagation and the canonical wave structure are maintained, with the wave-coolant interaction depending systematically on the coolant medium. Air injection causes the greatest disturbance to the initiation region and downstream wave interactions, yielding the largest propulsion penalty. The cooling strategies substantially reduce the near-wall thermal load but produce distinct wall-temperature distributions. Gaseous-kerosene cooling yields a spatially periodic response from the discrete injection slots, whereas liquid-kerosene mist cooling gives a smoother and lower near-wall temperature through two-phase mixing and phase-change heat absorption. Liquid-kerosene mist cooling provides the most favorable balance between thermal protection and propulsion performance at low to moderate injection levels. With further increases in injection level, the thermal benefit approaches saturation while the propulsion penalty continues to grow: the mean near-wall fluid temperature reduction remains about 87% across both the inter-slot and cooling-slot wall segments, whereas the total specific impulse is reduced by about 3%-5%. These results quantify the thermal-propulsive trade-off across film-cooling media and demonstrate the potential of fuel-based cooling for thermal management in hypersonic ODE combustors.

physics.flu-dyn↗