Search arXiv⌕ Search

arXiv · 2610.21252

Finite-History Outage Certification for Partially Observed Fluid Antenna Receivers

Abstract

Fluid antenna receivers can select a service position from partial port observations, but finite historical data leave uncertainty in the covariance used for that decision. We develop deployment-before-use reliability certification for a frozen partial-observation rule. A proper predictive density defines a history-based parameter region. Gaussian covariance envelopes, shared conditional-probability bounds and selector enclosures provide simultaneous risk bounds over continuous parameters and discontinuous port decisions. Separate history-coverage and integration budgets limit erroneous positive certification to 0.05 for a single qualification procedure under the stated stationary model and numerical assumptions. Confidence-set inclusion allows a new independent history to reuse the risk computation with the rule unchanged. In a structured Gaussian example with 32 candidate positions, five noisy probes and target outage 0.001, all 282 risk groups are qualified; the largest upper bound is 0.000999748. A separate coupled comparison gives a current-rule outage interval of $[7.6820,9.1266]\times10^{-4}$ and resolves lower outage than two observed-port controls using the same historical fit. One independently recalibrated history reuses the certificate without additional risk sampling. Unresolved and adverse-member controls delimit this reuse.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yuanjun Shen. 2026-10-15. Finite-History Outage Certification for Partially Observed Fluid Antenna Receivers. https://arxiv.org/abs/2610.21252

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Probability of Error Analysis for NOMA Systems in Rayleigh Fading Channels: Enabling IoT in Civil Engineering

In the realm of digital communication, understanding and mitigating the probability of error is crucial, particularly in Rayleigh fading channels where signal impairments are common. This paper presents a unified approach to derive the probability of error formulations for two-users NOMA systems operating in Rayleigh fading channels. The methodologies and findings outlined in this study are essential for IoT applications in construction and civil engineering. Specifically, the derived error probability formulations can be employed to enhance the reliability and efficiency of IoT-based monitoring systems in these sectors. By optimizing communication protocols, the proposed approach ensures accurate data transmission, thereby facilitating real-time monitoring and decision-making processes in construction sites and civil infrastructure projects.

eess.SP↗

Hybrid Resource Allocation Scheme for Bistatic ISAC with Data Channels

Bistatic integrated sensing and communication (ISAC) enables efficient reuse of the existing cellular infrastructure and is likely to play an important role in future sensing networks. In this context, ISAC using the data channel is a promising approach to improve the bistatic sensing performance compared to relying solely on pilots. One of the challenges associated with this approach is resource allocation: the communication link aims to transmit higher modulation order (MO) symbols to maximize the throughput, whereas a lower MO is preferable for sensing to achieve a higher signal-to-noise ratio in the radar image. To address this conflict, this paper introduces a hybrid resource allocation scheme. By placing lower MO symbols as pseudo-pilots on a suitable sensing grid, we enhance the bistatic sensing performance while only slightly reducing the spectral efficiency of the communication link. Simulation results validate our approach against different baselines and provide practical insights into how decoding errors affect the sensing performance.

eess.SP↗

An auscultation location specific study on the relationship between expiratory-to-inspiratory acoustic patterns and spirometric airflow limitation across age and gender in asthmatic patients

Asthma causes expiratory airflow limitation and is clinically assessed using spirometry, which provides the FEV1/FVC ratio representing the proportion of air exhaled in the first second relative to total forced vital capacity. Prior studies suggest that respiratory sounds recorded at posterior sites (Left Lower, Left Upper, Right Upper, Right Lower) reflect regional airflow patterns. In this study, we investigate the relationship between the expiratory-to-inspiratory (E/I) spectral power ratio and FEV1/FVC in 141 participants aged 20-60 years using Spearman correlation across frequency subbands. The 100-200 Hz and 200-400 Hz bands showed significant correlations. Overall, lower posterior sites showed stronger associations; younger adults showed stronger correlations at the Left Lower site, whereas older adults showed stronger correlations at the Left Upper site. Gender-stratified analysis showed stronger Left Lower correlations in males and stronger Left Upper correlations in females.

eess.SP↗