Search arXiv⌕ Search

arXiv · 2610.28923

Experimental Characterization of SMD Inductors for Cryogenic Power Conversion at 4 K

Abstract

With the increasing complexity and scalability demands of cryogenic electronic systems, such as quantum computing platforms, conversion of power within the cryogenic environment has become a primary concern. Magnetic inductors are among the key components affecting converter performance, as their electrical and magnetic properties can change significantly at low temperatures. In this paper, five commercially available Vishay SMD power inductors are experimentally characterized down to 4 K: DC resistance is measured continuously during cooldown, while frequency-dependent AC inductance and resistance are measured up to 2 MHz at both room temperature and 4 K. The results show substantial DC resistance reductions of 25x-58x at 4 K, while the inductance degrades by only about 5-5.5%. Although cryogenic operation slightly increases the AC resistance (due to the intensified skin effect) and raises core losses, converter-level analysis shows an inductor-only efficiency improvement of approximately 5.3-6.9 percentage points at 1 A, and up to 22.8 points at 3 A. The measured frequency-dependent impedance of each inductor is imported into Cadence and a complete single-phase 24 V-to-1 V buck converter with GaN power devices is simulated at 1, 2, and 3 A at 4 K. The full-converter efficiency at 4 K is shown to improve by 3.0-5.2 percentage points at 1 A and by up to 22.5 points at 3 A for the AC-characterized devices. These findings indicate that commercially available off-the-shelf power inductors remain operationally viable under cryogenic conditions and can simultaneously increase inductor efficiency and reduce the overall power loss in cryogenic power conversion systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rami Rasheedi, Umeshkumar Patel, Jonathan Baldwin, Antonino Miceli, Inna Partin-Vaisband. 2026-10-20. Experimental Characterization of SMD Inductors for Cryogenic Power Conversion at 4 K. https://arxiv.org/abs/2610.28923

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Optimal Control of Behavioral-Feedback SIR Epidemic Model

We consider a behavioral-feedback SIR epidemic model, in which the infection rate depends in feedback on the fractions of susceptible and infected agents. Contrary to the classic SIR dynamics, the considered model allows one to account for endogenous adaptation mechanisms of the agents in response to the epidemics, such as voluntary social distancing, or the adoption of face masks. For this model, we formulate an optimal control problem for a social planner that has the ability to reduce the infection rate to keep the infection curve below a certain threshold within an infinite time horizon, while minimizing the intervention cost. Based on the dynamic properties of the model, we prove that, under quite general conditions on the infection rate, the filling-the-box strategy is the optimal control. This strategy consists in letting the epidemics spread without intervention until the threshold is reached, then applying the minimum control that leaves the fraction of infected individuals constantly at the threshold until the reproduction number becomes less than one and the infection naturally fades out. Our contribution enhances the understanding of epidemic management while accounting for adaptive human behavior, offering novel insights for robust containment strategies.

eess.SY↗

The Cheap Hours Don't Stay Cheap: Price-Chasing Data Centers Reshape Grids and Markets

Data centers unsettle the paradigm of location-bound electricity demand: computing workloads can migrate across sites and hours, whereas facilities and grid connections remain fixed. This mobility reduces electricity costs but reshapes the spatiotemporal structure of nodal prices. A model-driven framework couples US wholesale market signals with optimal fleet scheduling, showing how their interaction alters prices and other participants' responses. Greater flexibility enlarges savings yet can erode network benefits: in a Texas study, temporal shifting and cross-site allocation each relieve congestion, but their combination leaves total congestion nearly unchanged. At continental scale, computing demand gravitating toward cheaper electricity narrows price differences and compresses the low-price hours storage arbitrage relies on, threatening storage investment recovery. Cost-minimizing scheduling may therefore undermine grid-supporting resources. Comparing job-level and aggregate fleet representations reveals a trade-off between operational visibility and information disclosure, informing requirements and incentives that could turn workload mobility into a lever for system-wide efficiency.

eess.SY↗

Traffic State Prediction and Control Using a Koopman Operator Framework with Polynomial Observables

In this paper, we develop a Koopman operator framework for modeling and control of traffic flow governed by the Lighthill--Whitham--Richards (LWR) conservation law. We show that the nonlinear dynamics induced by the Greenshields flow--density relation naturally motivate a dictionary of polynomial observables, while the controlled dynamics become bilinear in the lifted Koopman coordinates. A reduced-order Koopman model is identified from spatio-temporal traffic-density snapshots and used as the prediction model in a model predictive control (MPC) framework for ramp metering. The resulting Koopman-MPC is compared with two predictive control baselines that use, respectively, a fixed linearized LWR model and the nonlinear finite-volume LWR model. In a one-hour freeway experiment, the Koopman-based controller maintains the traffic density below the critical Greenshields value and closely reproduces the behavior of the nonlinear PDE-based MPC, with a maximum-density difference below 1%. The Koopman predictor also reduces the mean online model-evaluation cost by approximately one order of magnitude relative to the nonlinear PDE predictor. In contrast, the linearized LWR predictor is computationally cheaper but exhibits substantially larger prediction errors and yields a more conservative metering policy. These results demonstrate that the analytical structure of the nonlinear traffic conservation law can be exploited to construct an interpretable data-driven surrogate for efficient traffic prediction and control

eess.SY↗