Search arXiv⌕ Search

arXiv · 2610.32533

Enabling 3GPP-Driven Services Over Optical Transport Network

Abstract

We demonstrate a multi-layer slicing architecture enabling deployment of 3GPP network slices as self-contained, connected functions atop optical transport slices. The system provides Optical Spectrum as a Service (OSaaS) by integrating disaggregated optical control, multi-tenant orchestration, and telemetry-based optimization via standard interfaces.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Renato Ambrosone, Ramon Casellas, Alessio Giorgetti, Riccardo Schips, Stefano Straullu, Pablo Armingol Robles, Óscar González de Dios, Francisco Javier Moreno, Enrique Fernandez, José Manuel Rivas-Moscoso, Francesco Aquilino, Antonino Nespola, Vittorio Curri. 2026-10-23. Enabling 3GPP-Driven Services Over Optical Transport Network. https://arxiv.org/abs/2610.32533

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Controller-Agnostic Runtime Safety Certificates for Tool-Using AI Agents via Data-Driven Robust Reachability

Software agents built on large language models act by issuing tool calls, some of which cannot be undone. To control theory the model is an opaque feedback controller, replaced every few months, whose closed loop cannot be analyzed directly. We propose a runtime filter, or shield, between any such controller and its environment that certifies a bound on the probability of reaching an unsafe condition during a bounded task. Given a predicate abstraction and candidate successor sets, everything else comes from logs: the loop becomes a finite controlled Markov chain, the estimated kernel is surrounded by a distribution-free confidence region, and robust reach-avoid value iteration runs over it. The certificate is probably approximately correct and uniform over controllers respecting the filter, so one model may replace another without recomputation. In all tested datasets the true risk stayed within certificate and budget; in a file-system sandbox the filter stays sound against a hazard the logs barely covered, where a plug-in baseline certifies safety and fails; and it holds seven controllers, three of them open-weights models, to zero unsafe outcomes in 1050 episodes.

eess.SY↗

Scalable Reservoir Computing for Disturbance Localization and Identification in Power Grids

In this paper, we present a novel method for the localization and temporal waveform reconstruction of disturbances in complex power grids using observations of system state variables. Although various methods exist for detecting these events, accurately identifying and responding to them remains a significant challenge due to the grid's size, speed, complexity, and inherently dynamic behavior. We formulate a method for disturbance localization and reconstruction based on reservoir computing, a recurrent neural network architecture. We show that our method is able to recover the time dependence of previously unobserved disturbances, is robust to missing information, and can operate online. The approach requires only observed system data and knowledge of the network topology, without requiring a physical model of the system dynamics, and can recover simultaneous disturbances occurring at multiple locations. We implement a scalable parallelized reservoir architecture and demonstrate our algorithm on test IEEE cases and a reduced WECC system.

eess.SY↗

Stability Enhancement of Cascaded DC Systems via Source Output-Impedance Reshaping Using Model-Free Control

Cascaded DC systems may become unstable through source-load impedance interactions even when their constituent converters are locally stable. This paper proposes a source-side model-free control (MFC) method that reuses bus-voltage feedback to reshape the source output impedance while preserving nominal reference-to-output dynamics. The controller uses only nominal source-loop information and requires neither a load-converter model nor load-side measurements. A current-controlled buck source supplying a regulated buck-resistor load that exhibits constant-power load (CPL) behaviour at low frequencies is used as the case study. Impedance analysis predicts that the proposed MFC increases the maximum stable load power by approximately 50%, thereby improving the stability margin of the cascaded system. Switched-model simulations confirm preservation of the nominal reference-to-output response and show that the MFC-controlled system remains stable at load levels for which the baseline system becomes unstable.

eess.SY↗