Search arXiv⌕ Search

arXiv · 2611.05618

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bowen Xiang. 2026-11-12. When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy. https://searcharxiv.org/abs/2611.05618

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

UHD Low-Light Image Enhancement via Real-Time Enhancement Methods with Clifford Information Fusion

Considering efficiency, ultra-high-definition (UHD) low-light image restoration is extremely challenging. Existing methods based on Transformer architectures or high-dimensional complex convolutional neural networks often suffer from the "memory wall" bottleneck, failing to achieve millisecond-level inference on edge devices. To address this issue, we propose a novel real-time UHD low-light enhancement network based on geometric feature fusion using Clifford algebra in 2D Euclidean space. First, we construct a four-layer feature pyramid with gradually increasing resolution, which decomposes input images into low-frequency and high-frequency structural components via a Gaussian blur kernel, and adopts a lightweight U-Net based on depthwise separable convolution for dual-branch feature extraction. Second, to resolve structural information loss and artifacts from traditional high-low frequency feature fusion, we introduce spatially aware Clifford algebra, which maps feature tensors to a multivector space (scalars, vectors, bivectors) and uses Clifford similarity to aggregate features while suppressing noise and preserving textures. In the reconstruction stage, the network outputs adaptive Gamma and Gain maps, which perform physically constrained non-linear brightness adjustment via Retinex theory. Integrated with FP16 mixed-precision computation and dynamic operator fusion, our method achieves millisecond-level inference for 4K/8K images on a single consumer-grade device, while outperforming state-of-the-art (SOTA) models on several restoration metrics.

eess.IV↗

TransGHOST: Real-Time, Synthesis-Free Reconstruction of Instrument-Occluded Regions in Ophthalmic Microsurgery

Intraoperative scene perception in ophthalmic microsurgery is limited by instrument occlusion: when a tool enters the high-magnification field, it conceals tissue from both the surgeon and the perception components of robot-assisted systems that process the video. Generative inpainting can remove the occluder but replaces the missing image content with synthesis, which is unsuitable when visual provenance matters. Many video inpainters also depend on future frames and cannot operate online. We present TransGHOST, a causal reference-guided reconstruction pipeline whose non-generative safe mode operates in real time. Every restored value is obtained by resampling a recorded frame using geometric transforms fitted only to visible regions. The system provides per-pixel confidence and provenance and marks unsupported pixels as abstentions. We evaluate TransGHOST on a new veterinary clinical corpus of canine cataract surgery with pixel-level instrument and anatomy labels. Only the occluded region is scored, and each scoring target is verified to differ from the reference supplied to the system. Safe mode reaches 31.89 dB masked PSNR and 0.915 masked SSIM at 51.7 ms median and 85.5 ms 95th-percentile latency. On a pre-declared held-out cohort using instrument cutouts excluded from segmentation training, it reaches 29.83 dB masked PSNR, while matched-mask evaluation on validation shows a 3.45 dB advantage over LaMa. Region-aware reference selection improves masked PSNR by 3.60 dB over recency when candidate references can themselves be occluded. Reference-age analysis further defines the operating interval for the brief, repeated occlusions targeted by TransGHOST.

eess.IV↗

Angel: Anchor-Structured Neural Gaussians for Explicit Fetal Diffusion MRI Slice-to-Volume Reconstruction with Cross-Subject Learning

Diffusion magnetic resonance imaging (dMRI) provides a noninvasive view of developing tissue microstructure and white matter tracts in the fetal brain. During acquisition, however, fetal motion disrupts spatial correspondence between slices, diffusion encoding directions and signal intensities. We introduce ANGEL, an anchor-structured neural Gaussian framework for accurate slice-to-volume reconstruction (SVR) of fetal dMRI, that simultaneously estimates diffusion signal, fetal motion and intensity artefacts. Unlike standard explicit Gaussian representation, ANGEL is designed to prevent absorption of noise and artefacts into the reconstructed dMRI by learning a compact representation of spatio-angular signal via a shared decoder that predicts 3D Gaussians across anchors and subjects. The individual anatomical variability is compactly represented through subject-specific anchors. Experiments on simulated neonatal and in vivo fetal data show significant improvement of dMRI reconstruction in both spatial and angular domains, in comparison to explicit Gaussian representation, implicit neural representation as well as classical methods.

eess.IV↗