Search arXiv⌕ Search

arXiv · 2611.11716

Rapid Heat Removal from Chip Cores: Near-Junction Active Cooling of Power Transistors via Electron Entropy Transport and Spatial Decoupling

Abstract

Chip performance is limited by a shared bottleneck: the core produces heat faster than it can be moved out. We study the hardest case, RF power GaN HEMTs, whose hotspots exceed 5 kW/cm^2, and propose a horizontal near-junction active cooling topology built on electron entropy transport. Classical on-chip thermoelectric cooling faces a contest: Peltier absorption grows linearly with current, Joule heating with its square. In a vertical pillar, its own conduction resistance locks about half the Joule heat back toward the cold end, capping net cooling. From the Onsager framework we show the origin of this asymmetry: Peltier absorption localizes at the interface where the Seebeck coefficient jumps, whereas Joule heating fills the volume. The topology exploits this: a thermoelectric thin film lies flat on a diamond substrate beside the device drain (the electron exit), so bulk Joule heat leaves vertically into the substrate. A lateral fin model gives a closed form for the recirculation factor gamma: the vertical pillar yields gamma = 1, while the horizontal film yields gamma_max = sqrt(2) L_z/L_x, about 0.03 for L_z = 10 um, L_x = 500 um. The decoupling scales the net cooling ceiling and the critical runaway current by roughly 1/gamma. At equal resistance, the same film lifts maximum cooling from 13 mW to 500 mW, and the critical current from 0.65 A to 24 A. A time-constant and linear stability analysis with temperature-sensitive parameters defines the working window and safety margins for microsecond pulse cooling. The architecture leaves the device structure untouched; the principle, absorb at an interface and extract bulk heat vertically, applies to any chip with a hot core and offers a reproducible design path for near-junction thermal management.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Xiangying Li. 2026-11-09. Rapid Heat Removal from Chip Cores: Near-Junction Active Cooling of Power Transistors via Electron Entropy Transport and Spatial Decoupling. https://searcharxiv.org/abs/2611.11716

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

The Cesàro Value Iteration

In this paper, we consider undiscouted infinite-horizon optimal control for deterministic systems with an uncountable state and input space. We specifically address the case when the classic value iteration does not converge. For such systems, we use the Ces`aro mean to define the infinite-horizon optimal control problem and the corresponding infinite-horizon value function. Moreover, for this value function, we introduce the Cesàro value iteration and prove its convergence for the special case of systems with periodic optimal operating behavior. For this instance, we also show that the Cesàro value function recovers the undiscounted infinite-horizon optimal cost, if the latter is well-defined.

eess.SY↗

Comfort energy management system for electrified buildings using hydrogen for seasonal storage

Flexible loads and integrated energy storage in electrified buildings can align volatile renewable energy use with consumption. While battery energy storage systems provide short-term flexibility, hydrogen storage enables seasonal energy shifting. However, since hydrogen systems are expensive, coupling a fuel cell with a heat pump can reduce the required size of the hydrogen system and, therefore, investment costs. To fully exploit the flexibility of this integrated energy system, advanced control strategies are needed. This study proposes a comfort-oriented and grid-aware energy management system for an electrified building equipped with photovoltaics, a battery energy storage system, a hydrogen system, a heat pump, and domestic hot water storage. A novel fuzzy logic-based controller coordinates fuel cell and heat pump operation while exploiting building thermal mass as a flexibility resource. The proposed approach bridges the gap between simple rule-based control and model predictive control, enabling adaptive operation without system models, weather and demand forecasts, or high computational effort. The controller is evaluated over twelve winter weeks for a German single-family household and benchmarked against a rule-based controller and an ideal-forecast model predictive controller. Results show improved thermal comfort and lower electricity costs compared to the rule-based controller. Compared to model predictive control, the proposed controller reduces fuel cell operating hours and toggling counts, leading to more practical system operation. Overall, the proposed controller achieves a favorable trade-off between control performance and implementation complexity, combining low information requirements with improved comfort, storage use, and coordinated fuel cell-heat pump operation.

eess.SY↗

A Heuristic for Scheduling Autonomous Vehicles at Intersections

We consider the coordination of autonomous vehicles at unsignalized intersections, where trajectory planning and crossing-order decisions are intrinsically coupled, thereby making their simultaneous optimization intractable in practice. To this end, we propose a heuristic based on a hierarchical structure consisting of a series of nonlinear programs (NLP) in the lower level, which optimizes trajectories of each vehicle for a given crossing order, and a high-level heuristic to design new crossing schedules that exploits sensitivity information from the lower-level NLPs. Extensive numerical simulations across a broad range of traffic scenarios demonstrate that our strategy achieves substantially improved scheduling with respect to first-in-first-out ordering while preserving computational tractability.

eess.SY↗