Search arXiv⌕ Search

arXiv · 2611.13153

Fast Sampling or High Gain? iP versus PI Control

Abstract

Intelligent proportional (iP) controllers, introduced in the framework of model-free control, are often presented as an alternative to proportional-integral (PI) controllers that requires no model of the plant. This paper studies this property for a first-order linear plant under sampled-data implementation with a zero-order hold. When the time derivative of the output is estimated by a backward difference, the discrete-time iP and PI controllers are known to obey the same control law under a one-to-one correspondence between their parameters. Building on this correspondence, the paper derives necessary and sufficient conditions for exponential stability of the iP closed loop, in closed form, in terms of the controller parameters KP and alpha, the sampling period h, and the plant parameters. It then shows that, when the iP parameters are held fixed and the sampling period tends to zero, the closed-loop decay rate tends to the iP gain KP, provided that KP is positive and that the ratio rho between the input gain of the plant and alpha satisfies 0 < rho < 2. One closed-loop pole then behaves as 1 - h KP, while the other tends to 1 - rho. With fixed PI gains, by contrast, the decay rate tends to that of the continuous-time PI loop, which depends on the plant parameters. The two parametrizations therefore suggest different tuning procedures, although they achieve the same closed loops at every fixed sampling period. High gain for the PI is, in some sense, replaced by fast sampling of the iP. The results also make explicit which plant information the iP controller requires: the sign of the input gain and a bound on its magnitude in the limit of fast sampling, and bounds on both plant parameters at a given sampling period. Numerical experiments illustrate these results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mohamed Camil Belhadjoudja. 2026-11-09. Fast Sampling or High Gain? iP versus PI Control. https://searcharxiv.org/abs/2611.13153

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

The Cesàro Value Iteration

In this paper, we consider undiscouted infinite-horizon optimal control for deterministic systems with an uncountable state and input space. We specifically address the case when the classic value iteration does not converge. For such systems, we use the Ces`aro mean to define the infinite-horizon optimal control problem and the corresponding infinite-horizon value function. Moreover, for this value function, we introduce the Cesàro value iteration and prove its convergence for the special case of systems with periodic optimal operating behavior. For this instance, we also show that the Cesàro value function recovers the undiscounted infinite-horizon optimal cost, if the latter is well-defined.

eess.SY↗

Comfort energy management system for electrified buildings using hydrogen for seasonal storage

Flexible loads and integrated energy storage in electrified buildings can align volatile renewable energy use with consumption. While battery energy storage systems provide short-term flexibility, hydrogen storage enables seasonal energy shifting. However, since hydrogen systems are expensive, coupling a fuel cell with a heat pump can reduce the required size of the hydrogen system and, therefore, investment costs. To fully exploit the flexibility of this integrated energy system, advanced control strategies are needed. This study proposes a comfort-oriented and grid-aware energy management system for an electrified building equipped with photovoltaics, a battery energy storage system, a hydrogen system, a heat pump, and domestic hot water storage. A novel fuzzy logic-based controller coordinates fuel cell and heat pump operation while exploiting building thermal mass as a flexibility resource. The proposed approach bridges the gap between simple rule-based control and model predictive control, enabling adaptive operation without system models, weather and demand forecasts, or high computational effort. The controller is evaluated over twelve winter weeks for a German single-family household and benchmarked against a rule-based controller and an ideal-forecast model predictive controller. Results show improved thermal comfort and lower electricity costs compared to the rule-based controller. Compared to model predictive control, the proposed controller reduces fuel cell operating hours and toggling counts, leading to more practical system operation. Overall, the proposed controller achieves a favorable trade-off between control performance and implementation complexity, combining low information requirements with improved comfort, storage use, and coordinated fuel cell-heat pump operation.

eess.SY↗

A Heuristic for Scheduling Autonomous Vehicles at Intersections

We consider the coordination of autonomous vehicles at unsignalized intersections, where trajectory planning and crossing-order decisions are intrinsically coupled, thereby making their simultaneous optimization intractable in practice. To this end, we propose a heuristic based on a hierarchical structure consisting of a series of nonlinear programs (NLP) in the lower level, which optimizes trajectories of each vehicle for a given crossing order, and a high-level heuristic to design new crossing schedules that exploits sensitivity information from the lower-level NLPs. Extensive numerical simulations across a broad range of traffic scenarios demonstrate that our strategy achieves substantially improved scheduling with respect to first-in-first-out ordering while preserving computational tractability.

eess.SY↗