Search arXiv⌕ Search

arXiv · 2611.13830

SiPM optical readout of a PICOSEC Micromegas precise timing detector

Abstract

By combining a Cherenkov radiator with a semi-transparent photocathode and a two-stage Micromegas amplification element, PICOSEC Micromegas detectors have achieved <20 ps charged-particle time resolution with electronic readout of induced signals. Building upon this performance, we describe SiPM-based optical readout as a novel technique for PICOSEC Micromegas detectors. Single-channel detector prototypes based on glass Micromegas technology were read out with an array of SiPMs. To allow operation in a strongly quenched gas mixture, a solid wavelength shifter is integrated in the glass Micromegas to convert UV scintillation to the visible range and maximise scintillation light output. Timing performance of glass Micromegas in electronic and optical readout modes is compared and <150 ps time resolution is achieved by optically read out scintillation light signals. The achievable spatial resolution from centre-of-gravity reconstruction of event positions from the amplitudes of signals on multiple SiPM channels is σ = 1.25 mm. This demonstrates the possibility of dual-readout of PICOSEC glass Micromegas: electronic signals and optical signals. Finally, camera-based optical readout is presented to demonstrate imaging as another avenue for position reconstruction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F. M. Brunbauer, R. Aleksan, S. Aune, J. Bortfeldt, A. Breskin, M. Brunoldi, J. Datta, G. Fanourakis, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, F. Guerra, D. Janssens, E. Jelinkova, A. Kallitsopoulou, I. Karakoulias, M. Kovacic, P. Legou, M. Lisowska, J. Liu, M. Lupberger, D. J. G. Marques, H. Muller, E. Oliveri, T. Papaevangelou, M. Pomorski, L. Ropelewski, D. Sampsonidis, T. Schneider, B. Schoenfelder, E. Scorsone, M. van Stenis, Y. Tsipolitis, S. Tzamarias, A. Utrobicic, I. Vai, R. Veenhof, P. Vitulo, X. Wang, S. White, D. Zavazieva, Z. Zhang, Y. Zhou. 2026-11-10. SiPM optical readout of a PICOSEC Micromegas precise timing detector. https://searcharxiv.org/abs/2611.13830

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Design of an electrostatic violin mode damper for gravitational wave detector enhancement

The test mass suspension fiber resonances and their harmonics pollute the sensitivity of the detectors of the advanced Laser Interferometer Gravitational Wave Observatory (aLIGO) and cause operational issues. The current method of damping these violin modes requires the GW detector be locked; identifying modes after a test mass replacement takes valuable commissioning time, and modes which are close together in frequency are hard to distinguish and damp independently. We present the design, prototyping, and initial lab testing of an electrostatic violin mode damper: a compact sensor and actuator set next to the fiber to monitor and damp resonances. The design uses a split photodiode and LED integrated into a shadow sensor, and an electrostatic actuator. The device is vacuum compatible and its mechanical design is compatible with the suspension and surrounding cage of the advanced Laser Interferometer Gravitational Wave Observatory test masses. The shadow sensor has a shot noise limited displacement noise floor of 5e-11 {\meter\per\sqrt\hertz}, sufficient to measure the test mass violin modes when highly excited. The modeled actuator strength is 0.3 nN, meeting the requirements to damp the modes for the aLIGO suspensions.

physics.ins-det↗

Compact GridPix Tracking: Test Beam Performance and Detector Response Modelling

We characterise a Timepix-based GridPix detector with a 21 mm drift length using 2.6 GeV electrons at ELSA. Tracks entering through the window at several angles are reconstructed as compact $μ$TPC tracklets, providing position and local direction from one layer. Measured angular widths are approximately 5--10 mrad. An empirical response model calibrated to these data augments Geant4 ionisation information with gas-transport and readout effects, reproducing ten of twelve angular widths within approximately 20% and all spatial-residual widths within approximately 12%. Application without re-tuning to an independent 5 mm-drift measurement shows larger angular discrepancies. Our response model therefore provides input to feasibility studies of future compact tracking detectors.

physics.ins-det↗

Simulation Study of the MPD Performance for Dielectron Measurements at NICA

The Multi-Purpose Detector (MPD) experiment at NICA is designed to investigate strongly interacting matter at high net-baryon density through a broad program of heavy-ion measurements. Dielectrons constitute one of the key probes in this program, with contributions emitted throughout the entire space-time evolution of the collision. Their experimental measurement is, however, challenged by a large combinatorial background arising primarily from incompletely reconstructed photon conversions and Dalitz decays of light neutral mesons. In this work, we study the expected performance and capabilities of the MPD experiment for dielectron measurements using simulated minimum-bias $^{209}$Bi+$^{209}$Bi collisions at $\sqrt{s_{NN}}$ = 9.2 GeV. Electron identification is performed using the combined information from the TPC, the TOF detector and the ECal. A previously developed multilayer-perceptron classifier is used for electron identification, providing a substantial increase in electron detection efficiency relative to sequential one-dimensional selections while preserving an electron-sample purity close to unity. To address the dominant sources of combinatorial background, a pair-analysis strategy is developed that exploits partially reconstructed electron tracks. The method combines the pair opening angle, the TPC dE/dx signal, and an approximate reconstruction of the pair invariant mass to tag tracks from photon conversions and $π^0$ Dalitz decays at the pair level. In the mass interval 0.2 $< m_{ee}<0.7 $ GeV/$c^2$, the method improves the signal-to-background ratio by a factor of about 3.5 with the current track reconstruction algorithm. The study demonstrates the strong potential of the MPD experiment for dielectron measurements at NICA energies and highlights the importance of further improvements in low-$p_{\rm T}$ track reconstruction.

physics.ins-det↗