Search arXiv⌕ Search

arXiv · 2611.13970

Counterfactual Analysis of Extent Leakage from Annotation-Derived Prompts in Vision-Language Medical Image Segmentation

Abstract

Text-guided segmentation models receive an image and a short caption about the lesion, and on public benchmarks the caption improves accuracy considerably. On colonoscopy and breast ultrasound, however, the size, count and location words of each caption were computed from the mask that later scores the prediction, and the chest X-ray captions were written by benchmark annotators. We tested what two published models take from them. On colonoscopy and chest X-ray, it is mostly the lesion's extent. Keeping only the size word or the lung-zone phrase recovers 84 to 98 percent of the improvement over an empty caption, and removing it loses 52 to 77 percent. The rest matters little, and a polyp called a rock is segmented just as well. We call this extent leakage. On breast ultrasound, nearly half the captions also name the diagnosis, which carries part of the benefit. Retraining on three datasets shows that models pick up this habit from their training captions, though only partly on breast ultrasound, and that it weakens their segmentation from the image alone. The leak can be measured without training a model, since caption words alone predict lesion area (coefficient of determination 0.54 to 0.77 on six of seven test sets). Without the test mask, the best method we tested, which estimates extent from the image, reaches 74.59 Dice on colonoscopy against the published 77.23. We propose an evaluation protocol that keeps what a caption says about the image apart from what it copies from the label.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Niran Nataraj, Ankita Das, C. Krishna Mohan, Kenji Kawashima. 2026-11-10. Counterfactual Analysis of Extent Leakage from Annotation-Derived Prompts in Vision-Language Medical Image Segmentation. https://searcharxiv.org/abs/2611.13970

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

UHD Low-Light Image Enhancement via Real-Time Enhancement Methods with Clifford Information Fusion

Considering efficiency, ultra-high-definition (UHD) low-light image restoration is extremely challenging. Existing methods based on Transformer architectures or high-dimensional complex convolutional neural networks often suffer from the "memory wall" bottleneck, failing to achieve millisecond-level inference on edge devices. To address this issue, we propose a novel real-time UHD low-light enhancement network based on geometric feature fusion using Clifford algebra in 2D Euclidean space. First, we construct a four-layer feature pyramid with gradually increasing resolution, which decomposes input images into low-frequency and high-frequency structural components via a Gaussian blur kernel, and adopts a lightweight U-Net based on depthwise separable convolution for dual-branch feature extraction. Second, to resolve structural information loss and artifacts from traditional high-low frequency feature fusion, we introduce spatially aware Clifford algebra, which maps feature tensors to a multivector space (scalars, vectors, bivectors) and uses Clifford similarity to aggregate features while suppressing noise and preserving textures. In the reconstruction stage, the network outputs adaptive Gamma and Gain maps, which perform physically constrained non-linear brightness adjustment via Retinex theory. Integrated with FP16 mixed-precision computation and dynamic operator fusion, our method achieves millisecond-level inference for 4K/8K images on a single consumer-grade device, while outperforming state-of-the-art (SOTA) models on several restoration metrics.

eess.IV↗

TransGHOST: Real-Time, Synthesis-Free Reconstruction of Instrument-Occluded Regions in Ophthalmic Microsurgery

Intraoperative scene perception in ophthalmic microsurgery is limited by instrument occlusion: when a tool enters the high-magnification field, it conceals tissue from both the surgeon and the perception components of robot-assisted systems that process the video. Generative inpainting can remove the occluder but replaces the missing image content with synthesis, which is unsuitable when visual provenance matters. Many video inpainters also depend on future frames and cannot operate online. We present TransGHOST, a causal reference-guided reconstruction pipeline whose non-generative safe mode operates in real time. Every restored value is obtained by resampling a recorded frame using geometric transforms fitted only to visible regions. The system provides per-pixel confidence and provenance and marks unsupported pixels as abstentions. We evaluate TransGHOST on a new veterinary clinical corpus of canine cataract surgery with pixel-level instrument and anatomy labels. Only the occluded region is scored, and each scoring target is verified to differ from the reference supplied to the system. Safe mode reaches 31.89 dB masked PSNR and 0.915 masked SSIM at 51.7 ms median and 85.5 ms 95th-percentile latency. On a pre-declared held-out cohort using instrument cutouts excluded from segmentation training, it reaches 29.83 dB masked PSNR, while matched-mask evaluation on validation shows a 3.45 dB advantage over LaMa. Region-aware reference selection improves masked PSNR by 3.60 dB over recency when candidate references can themselves be occluded. Reference-age analysis further defines the operating interval for the brief, repeated occlusions targeted by TransGHOST.

eess.IV↗

Angel: Anchor-Structured Neural Gaussians for Explicit Fetal Diffusion MRI Slice-to-Volume Reconstruction with Cross-Subject Learning

Diffusion magnetic resonance imaging (dMRI) provides a noninvasive view of developing tissue microstructure and white matter tracts in the fetal brain. During acquisition, however, fetal motion disrupts spatial correspondence between slices, diffusion encoding directions and signal intensities. We introduce ANGEL, an anchor-structured neural Gaussian framework for accurate slice-to-volume reconstruction (SVR) of fetal dMRI, that simultaneously estimates diffusion signal, fetal motion and intensity artefacts. Unlike standard explicit Gaussian representation, ANGEL is designed to prevent absorption of noise and artefacts into the reconstructed dMRI by learning a compact representation of spatio-angular signal via a shared decoder that predicts 3D Gaussians across anchors and subjects. The individual anatomical variability is compactly represented through subject-specific anchors. Experiments on simulated neonatal and in vivo fetal data show significant improvement of dMRI reconstruction in both spatial and angular domains, in comparison to explicit Gaussian representation, implicit neural representation as well as classical methods.

eess.IV↗