Search arXiv⌕ Search

arXiv · 2611.15758

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng, Yang Zhou, Xiang Zhou, Tianyu He, Xinran Chen, Qiaoling Zeng, Keyan Yu, Jianhua Yao, Dong Liang. 2026-11-11. Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction. https://searcharxiv.org/abs/2611.15758

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

UHD Low-Light Image Enhancement via Real-Time Enhancement Methods with Clifford Information Fusion

Considering efficiency, ultra-high-definition (UHD) low-light image restoration is extremely challenging. Existing methods based on Transformer architectures or high-dimensional complex convolutional neural networks often suffer from the "memory wall" bottleneck, failing to achieve millisecond-level inference on edge devices. To address this issue, we propose a novel real-time UHD low-light enhancement network based on geometric feature fusion using Clifford algebra in 2D Euclidean space. First, we construct a four-layer feature pyramid with gradually increasing resolution, which decomposes input images into low-frequency and high-frequency structural components via a Gaussian blur kernel, and adopts a lightweight U-Net based on depthwise separable convolution for dual-branch feature extraction. Second, to resolve structural information loss and artifacts from traditional high-low frequency feature fusion, we introduce spatially aware Clifford algebra, which maps feature tensors to a multivector space (scalars, vectors, bivectors) and uses Clifford similarity to aggregate features while suppressing noise and preserving textures. In the reconstruction stage, the network outputs adaptive Gamma and Gain maps, which perform physically constrained non-linear brightness adjustment via Retinex theory. Integrated with FP16 mixed-precision computation and dynamic operator fusion, our method achieves millisecond-level inference for 4K/8K images on a single consumer-grade device, while outperforming state-of-the-art (SOTA) models on several restoration metrics.

eess.IV↗

TransGHOST: Real-Time, Synthesis-Free Reconstruction of Instrument-Occluded Regions in Ophthalmic Microsurgery

Intraoperative scene perception in ophthalmic microsurgery is limited by instrument occlusion: when a tool enters the high-magnification field, it conceals tissue from both the surgeon and the perception components of robot-assisted systems that process the video. Generative inpainting can remove the occluder but replaces the missing image content with synthesis, which is unsuitable when visual provenance matters. Many video inpainters also depend on future frames and cannot operate online. We present TransGHOST, a causal reference-guided reconstruction pipeline whose non-generative safe mode operates in real time. Every restored value is obtained by resampling a recorded frame using geometric transforms fitted only to visible regions. The system provides per-pixel confidence and provenance and marks unsupported pixels as abstentions. We evaluate TransGHOST on a new veterinary clinical corpus of canine cataract surgery with pixel-level instrument and anatomy labels. Only the occluded region is scored, and each scoring target is verified to differ from the reference supplied to the system. Safe mode reaches 31.89 dB masked PSNR and 0.915 masked SSIM at 51.7 ms median and 85.5 ms 95th-percentile latency. On a pre-declared held-out cohort using instrument cutouts excluded from segmentation training, it reaches 29.83 dB masked PSNR, while matched-mask evaluation on validation shows a 3.45 dB advantage over LaMa. Region-aware reference selection improves masked PSNR by 3.60 dB over recency when candidate references can themselves be occluded. Reference-age analysis further defines the operating interval for the brief, repeated occlusions targeted by TransGHOST.

eess.IV↗

Angel: Anchor-Structured Neural Gaussians for Explicit Fetal Diffusion MRI Slice-to-Volume Reconstruction with Cross-Subject Learning

Diffusion magnetic resonance imaging (dMRI) provides a noninvasive view of developing tissue microstructure and white matter tracts in the fetal brain. During acquisition, however, fetal motion disrupts spatial correspondence between slices, diffusion encoding directions and signal intensities. We introduce ANGEL, an anchor-structured neural Gaussian framework for accurate slice-to-volume reconstruction (SVR) of fetal dMRI, that simultaneously estimates diffusion signal, fetal motion and intensity artefacts. Unlike standard explicit Gaussian representation, ANGEL is designed to prevent absorption of noise and artefacts into the reconstructed dMRI by learning a compact representation of spatio-angular signal via a shared decoder that predicts 3D Gaussians across anchors and subjects. The individual anatomical variability is compactly represented through subject-specific anchors. Experiments on simulated neonatal and in vivo fetal data show significant improvement of dMRI reconstruction in both spatial and angular domains, in comparison to explicit Gaussian representation, implicit neural representation as well as classical methods.

eess.IV↗