Characterization of a Large-Area HRPPD MCP-PMT Coupled to LYSO for TOF-PET

Abstract

Large-area microchannel-plate photomultipliers (MCP-PMTs) such as the High-Rate Picosecond Photon Detector (HRPPD) are attractive for time-of-flight positron emission tomography (TOF-PET). They offer excellent single-photon time resolution, low dark count rate, and large monolithic active areas. However, the coincidence time resolution (CTR) reported so far with PET scintillators falls short of expectations based upon their single-photon time resolution. We characterized a 104x104 mm$^2$ HRPPD coupled to LYSO crystals and read out through a custom high-frequency amplifier. With a 2x2x3 mm$^3$ LYSO crystal we measured a CTR of 107 ps full width at half maximum (FWHM) against a silicon photomultiplier (SiPM)-based reference detector. After subtracting the calibrated reference detector's contribution of 42 ps, the single HRPPD detector was found to contribute 98 ps, corresponding to 139 ps for two identical HRPPD detectors in coincidence. With clinical 3x3x20 mm$^3$ crystals the CTR against the reference SiPM detector was 160 ps, corresponding to 218 ps for two identical HRPPD detectors. Timing and gain were uniform across output pads within measurement precision. Summing the four pads under a 3x3x10 mm$^3$ LYSO crystal, the energy resolution for 511 keV gamma ray was 14.6% FWHM, and the 1275 keV line of the $^{22}$Na source was within 1% of its proportional position relative to the 511 keV peak. Flood maps resolved the individual 3 mm elements of a 4x4 array despite the 25 mm pad pitch. To the best of our knowledge the observed timing resolution improves substantially on what has been reported for large-area MCP-PMTs coupled to PET scintillators, and the crystal array identification has not been demonstrated before on such a device. These results indicate that this device class deserves renewed consideration as a photodetector technology for high-performance TOF-PET systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yingjie Wang, Mark A. Popecki, Heejong Kim, Alexey V. Lyashenko, Stefan Cwik, Mythra Varun Nemallapudi, Jeffrey S. Souris, Michael J. Minot, Chien-Min Kao, Chin-Tu Chen. 2026-11-11. Characterization of a Large-Area HRPPD MCP-PMT Coupled to LYSO for TOF-PET. https://searcharxiv.org/abs/2611.15820

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Design of an electrostatic violin mode damper for gravitational wave detector enhancement

The test mass suspension fiber resonances and their harmonics pollute the sensitivity of the detectors of the advanced Laser Interferometer Gravitational Wave Observatory (aLIGO) and cause operational issues. The current method of damping these violin modes requires the GW detector be locked; identifying modes after a test mass replacement takes valuable commissioning time, and modes which are close together in frequency are hard to distinguish and damp independently. We present the design, prototyping, and initial lab testing of an electrostatic violin mode damper: a compact sensor and actuator set next to the fiber to monitor and damp resonances. The design uses a split photodiode and LED integrated into a shadow sensor, and an electrostatic actuator. The device is vacuum compatible and its mechanical design is compatible with the suspension and surrounding cage of the advanced Laser Interferometer Gravitational Wave Observatory test masses. The shadow sensor has a shot noise limited displacement noise floor of 5e-11 {\meter\per\sqrt\hertz}, sufficient to measure the test mass violin modes when highly excited. The modeled actuator strength is 0.3 nN, meeting the requirements to damp the modes for the aLIGO suspensions.

physics.ins-det↗

Compact GridPix Tracking: Test Beam Performance and Detector Response Modelling

We characterise a Timepix-based GridPix detector with a 21 mm drift length using 2.6 GeV electrons at ELSA. Tracks entering through the window at several angles are reconstructed as compact $μ$TPC tracklets, providing position and local direction from one layer. Measured angular widths are approximately 5--10 mrad. An empirical response model calibrated to these data augments Geant4 ionisation information with gas-transport and readout effects, reproducing ten of twelve angular widths within approximately 20% and all spatial-residual widths within approximately 12%. Application without re-tuning to an independent 5 mm-drift measurement shows larger angular discrepancies. Our response model therefore provides input to feasibility studies of future compact tracking detectors.

physics.ins-det↗

Simulation Study of the MPD Performance for Dielectron Measurements at NICA

The Multi-Purpose Detector (MPD) experiment at NICA is designed to investigate strongly interacting matter at high net-baryon density through a broad program of heavy-ion measurements. Dielectrons constitute one of the key probes in this program, with contributions emitted throughout the entire space-time evolution of the collision. Their experimental measurement is, however, challenged by a large combinatorial background arising primarily from incompletely reconstructed photon conversions and Dalitz decays of light neutral mesons. In this work, we study the expected performance and capabilities of the MPD experiment for dielectron measurements using simulated minimum-bias $^{209}$Bi+$^{209}$Bi collisions at $\sqrt{s_{NN}}$ = 9.2 GeV. Electron identification is performed using the combined information from the TPC, the TOF detector and the ECal. A previously developed multilayer-perceptron classifier is used for electron identification, providing a substantial increase in electron detection efficiency relative to sequential one-dimensional selections while preserving an electron-sample purity close to unity. To address the dominant sources of combinatorial background, a pair-analysis strategy is developed that exploits partially reconstructed electron tracks. The method combines the pair opening angle, the TPC dE/dx signal, and an approximate reconstruction of the pair invariant mass to tag tracks from photon conversions and $π^0$ Dalitz decays at the pair level. In the mass interval 0.2 $< m_{ee}<0.7 $ GeV/$c^2$, the method improves the signal-to-background ratio by a factor of about 3.5 with the current track reconstruction algorithm. The study demonstrates the strong potential of the MPD experiment for dielectron measurements at NICA energies and highlights the importance of further improvements in low-$p_{\rm T}$ track reconstruction.

physics.ins-det↗