Search arXiv⌕ Search

arXiv · 2611.17364

Study of neutron flux redistribution and shadowing effect in rod worth measurements with the rod drop experiment

Abstract

This study investigates neutron flux redistribution and the shadowing effect between control rods during rod-worth measurements using the rod-drop experiment. A simulation-based instrumental calibration methodology is proposed to account for spatial effects on neutron detector responses and improve the accuracy of reactivity measurements. The IPEN/MB-01 research reactor was modeled using the MCNP Monte Carlo neutron transport code. Reactivity behavior during the initial transient of the rod-drop experiment (t < 10 s) was evaluated and compared with experimental measurements using the source-jerk method. The methodology quantifies control rod shadowing and detector-dependent neutron flux redistribution, allowing correction factors to be established for the measured reactivity. Control-bank worth values obtained through the stable-period method were adopted as reference measurements. The reported maximum deviations from the reference values were 0.5% and 11.3%, respectively. The results demonstrate the relevance of spatial neutron flux effects, control rod interactions, and detector calibration in rod-drop experiments, providing a computational and experimental basis for improving control rod worth measurements in research reactors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Giovanni L. Stefani, Guilherme E. S. Carvalho, Daniel A. P. Palma, Marcelo V. Silva, Cesar Raitz. 2026-11-05. Study of neutron flux redistribution and shadowing effect in rod worth measurements with the rod drop experiment. https://doi.org/10.1016/j.nucengdes.2023.112672. https://searcharxiv.org/abs/2611.17364

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Design of an electrostatic violin mode damper for gravitational wave detector enhancement

The test mass suspension fiber resonances and their harmonics pollute the sensitivity of the detectors of the advanced Laser Interferometer Gravitational Wave Observatory (aLIGO) and cause operational issues. The current method of damping these violin modes requires the GW detector be locked; identifying modes after a test mass replacement takes valuable commissioning time, and modes which are close together in frequency are hard to distinguish and damp independently. We present the design, prototyping, and initial lab testing of an electrostatic violin mode damper: a compact sensor and actuator set next to the fiber to monitor and damp resonances. The design uses a split photodiode and LED integrated into a shadow sensor, and an electrostatic actuator. The device is vacuum compatible and its mechanical design is compatible with the suspension and surrounding cage of the advanced Laser Interferometer Gravitational Wave Observatory test masses. The shadow sensor has a shot noise limited displacement noise floor of 5e-11 {\meter\per\sqrt\hertz}, sufficient to measure the test mass violin modes when highly excited. The modeled actuator strength is 0.3 nN, meeting the requirements to damp the modes for the aLIGO suspensions.

physics.ins-det↗

Compact GridPix Tracking: Test Beam Performance and Detector Response Modelling

We characterise a Timepix-based GridPix detector with a 21 mm drift length using 2.6 GeV electrons at ELSA. Tracks entering through the window at several angles are reconstructed as compact $μ$TPC tracklets, providing position and local direction from one layer. Measured angular widths are approximately 5--10 mrad. An empirical response model calibrated to these data augments Geant4 ionisation information with gas-transport and readout effects, reproducing ten of twelve angular widths within approximately 20% and all spatial-residual widths within approximately 12%. Application without re-tuning to an independent 5 mm-drift measurement shows larger angular discrepancies. Our response model therefore provides input to feasibility studies of future compact tracking detectors.

physics.ins-det↗

Simulation Study of the MPD Performance for Dielectron Measurements at NICA

The Multi-Purpose Detector (MPD) experiment at NICA is designed to investigate strongly interacting matter at high net-baryon density through a broad program of heavy-ion measurements. Dielectrons constitute one of the key probes in this program, with contributions emitted throughout the entire space-time evolution of the collision. Their experimental measurement is, however, challenged by a large combinatorial background arising primarily from incompletely reconstructed photon conversions and Dalitz decays of light neutral mesons. In this work, we study the expected performance and capabilities of the MPD experiment for dielectron measurements using simulated minimum-bias $^{209}$Bi+$^{209}$Bi collisions at $\sqrt{s_{NN}}$ = 9.2 GeV. Electron identification is performed using the combined information from the TPC, the TOF detector and the ECal. A previously developed multilayer-perceptron classifier is used for electron identification, providing a substantial increase in electron detection efficiency relative to sequential one-dimensional selections while preserving an electron-sample purity close to unity. To address the dominant sources of combinatorial background, a pair-analysis strategy is developed that exploits partially reconstructed electron tracks. The method combines the pair opening angle, the TPC dE/dx signal, and an approximate reconstruction of the pair invariant mass to tag tracks from photon conversions and $π^0$ Dalitz decays at the pair level. In the mass interval 0.2 $< m_{ee}<0.7 $ GeV/$c^2$, the method improves the signal-to-background ratio by a factor of about 3.5 with the current track reconstruction algorithm. The study demonstrates the strong potential of the MPD experiment for dielectron measurements at NICA energies and highlights the importance of further improvements in low-$p_{\rm T}$ track reconstruction.

physics.ins-det↗