Search arXiv⌕ Search

arXiv · 2611.19860

Optimisation of gas mixture for charge and light readout with Micromegas detectors

Abstract

Optical readout of Micromegas detectors is a promising technique for neutron and charged-particle imaging, offering high spatial resolution while reducing the complexity of electronic readout. Within the framework of the development of optical-readout Micromegas detectors, different noble-gas-based mixtures have been investigated to optimize charge amplification and scintillation yield. Argon-, neon-, and helium-based mixtures with various quenchers were characterized using X-ray irradiation. The detector gain, energy resolution, and optical light intensity were measured simultaneously over a wide range of amplification fields. Unprecedented energy resolutions were achieved over a large detection area (several cm$^2$) with He/\CF and Ne/\CF (90/10) mixtures, reaching 10.5\% and 13.3\% (FWHM), respectively, with the He-based mixture delivering particularly remarkable performance. Simultaneous charge and optical measurements further reveal that high charge gain does not necessarily translate into a strong optical response: while He- and Ne-based mixtures achieve effective charge gains of the order of 10$^5$, Ar/\CF mixtures produce the strongest detected light signals. Among the investigated mixtures, the ternary Ar/\CF/Isobutane (95/3/2) mixture stands out as particularly promising, combining high effective charge gain, a comparatively strong optical response, and more stable detector operation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E. Fasoula F. Benedetti, A. Bonenfant, E. Casalotti, E. Chronopoulou, E. Ferrer-Ribas, A. Giganon, Y. Giomataris, B. Moreno, T. Papaevangelou, E. C. Pollacco. 2026-11-15. Optimisation of gas mixture for charge and light readout with Micromegas detectors. https://searcharxiv.org/abs/2611.19860

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Design of an electrostatic violin mode damper for gravitational wave detector enhancement

The test mass suspension fiber resonances and their harmonics pollute the sensitivity of the detectors of the advanced Laser Interferometer Gravitational Wave Observatory (aLIGO) and cause operational issues. The current method of damping these violin modes requires the GW detector be locked; identifying modes after a test mass replacement takes valuable commissioning time, and modes which are close together in frequency are hard to distinguish and damp independently. We present the design, prototyping, and initial lab testing of an electrostatic violin mode damper: a compact sensor and actuator set next to the fiber to monitor and damp resonances. The design uses a split photodiode and LED integrated into a shadow sensor, and an electrostatic actuator. The device is vacuum compatible and its mechanical design is compatible with the suspension and surrounding cage of the advanced Laser Interferometer Gravitational Wave Observatory test masses. The shadow sensor has a shot noise limited displacement noise floor of 5e-11 {\meter\per\sqrt\hertz}, sufficient to measure the test mass violin modes when highly excited. The modeled actuator strength is 0.3 nN, meeting the requirements to damp the modes for the aLIGO suspensions.

physics.ins-det↗

Compact GridPix Tracking: Test Beam Performance and Detector Response Modelling

We characterise a Timepix-based GridPix detector with a 21 mm drift length using 2.6 GeV electrons at ELSA. Tracks entering through the window at several angles are reconstructed as compact $μ$TPC tracklets, providing position and local direction from one layer. Measured angular widths are approximately 5--10 mrad. An empirical response model calibrated to these data augments Geant4 ionisation information with gas-transport and readout effects, reproducing ten of twelve angular widths within approximately 20% and all spatial-residual widths within approximately 12%. Application without re-tuning to an independent 5 mm-drift measurement shows larger angular discrepancies. Our response model therefore provides input to feasibility studies of future compact tracking detectors.

physics.ins-det↗

Simulation Study of the MPD Performance for Dielectron Measurements at NICA

The Multi-Purpose Detector (MPD) experiment at NICA is designed to investigate strongly interacting matter at high net-baryon density through a broad program of heavy-ion measurements. Dielectrons constitute one of the key probes in this program, with contributions emitted throughout the entire space-time evolution of the collision. Their experimental measurement is, however, challenged by a large combinatorial background arising primarily from incompletely reconstructed photon conversions and Dalitz decays of light neutral mesons. In this work, we study the expected performance and capabilities of the MPD experiment for dielectron measurements using simulated minimum-bias $^{209}$Bi+$^{209}$Bi collisions at $\sqrt{s_{NN}}$ = 9.2 GeV. Electron identification is performed using the combined information from the TPC, the TOF detector and the ECal. A previously developed multilayer-perceptron classifier is used for electron identification, providing a substantial increase in electron detection efficiency relative to sequential one-dimensional selections while preserving an electron-sample purity close to unity. To address the dominant sources of combinatorial background, a pair-analysis strategy is developed that exploits partially reconstructed electron tracks. The method combines the pair opening angle, the TPC dE/dx signal, and an approximate reconstruction of the pair invariant mass to tag tracks from photon conversions and $π^0$ Dalitz decays at the pair level. In the mass interval 0.2 $< m_{ee}<0.7 $ GeV/$c^2$, the method improves the signal-to-background ratio by a factor of about 3.5 with the current track reconstruction algorithm. The study demonstrates the strong potential of the MPD experiment for dielectron measurements at NICA energies and highlights the importance of further improvements in low-$p_{\rm T}$ track reconstruction.

physics.ins-det↗