Day-ahead load forecasts set balancing reserves, including the energy a pumped-storage plant holds against forecast errors. Both depend on three effects that are usually modeled separately, namely the thermal inertia of buildings, which makes load lag temperature, structural breaks, which shift demand, and the long memory of forecast errors, which keeps them from cancelling out. We prove that averaging building responses over Cole-Cole distributed time constants yields a fractional temperature kernel with nonnegative weights exactly when its order is at most one. A Bayesian information criterion that ignores long memory selects spurious breaks with probability tending to one, so breaks and memory are estimated jointly, and an online break detector keeps its false-alarm rate below any prescribed level. Long memory also makes the required storage energy grow faster than the square root of the horizon, so a second-order cone program schedules reserves from the joint distribution of hourly errors. On New England and Mid-Atlantic data including the 2020 pandemic, the proposed framework improves on the best of ten benchmarks by 15.7% and 10.3% in mean absolute percentage error. Its reserves breach the storage energy limit on 4.1% and 8.5% of days, against 36.7% and 57.5% with error correlations ignored.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ali Nikseresht. 2026-11-15. Physics-Informed Fractional Load Forecasting With Memory-Aware Break Detection for Reserve Scheduling. https://searcharxiv.org/abs/2611.19970

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search arXiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

The Cesàro Value Iteration

In this paper, we consider undiscouted infinite-horizon optimal control for deterministic systems with an uncountable state and input space. We specifically address the case when the classic value iteration does not converge. For such systems, we use the Ces`aro mean to define the infinite-horizon optimal control problem and the corresponding infinite-horizon value function. Moreover, for this value function, we introduce the Cesàro value iteration and prove its convergence for the special case of systems with periodic optimal operating behavior. For this instance, we also show that the Cesàro value function recovers the undiscounted infinite-horizon optimal cost, if the latter is well-defined.

eess.SY↗

Comfort energy management system for electrified buildings using hydrogen for seasonal storage

Flexible loads and integrated energy storage in electrified buildings can align volatile renewable energy use with consumption. While battery energy storage systems provide short-term flexibility, hydrogen storage enables seasonal energy shifting. However, since hydrogen systems are expensive, coupling a fuel cell with a heat pump can reduce the required size of the hydrogen system and, therefore, investment costs. To fully exploit the flexibility of this integrated energy system, advanced control strategies are needed. This study proposes a comfort-oriented and grid-aware energy management system for an electrified building equipped with photovoltaics, a battery energy storage system, a hydrogen system, a heat pump, and domestic hot water storage. A novel fuzzy logic-based controller coordinates fuel cell and heat pump operation while exploiting building thermal mass as a flexibility resource. The proposed approach bridges the gap between simple rule-based control and model predictive control, enabling adaptive operation without system models, weather and demand forecasts, or high computational effort. The controller is evaluated over twelve winter weeks for a German single-family household and benchmarked against a rule-based controller and an ideal-forecast model predictive controller. Results show improved thermal comfort and lower electricity costs compared to the rule-based controller. Compared to model predictive control, the proposed controller reduces fuel cell operating hours and toggling counts, leading to more practical system operation. Overall, the proposed controller achieves a favorable trade-off between control performance and implementation complexity, combining low information requirements with improved comfort, storage use, and coordinated fuel cell-heat pump operation.

eess.SY↗

A Heuristic for Scheduling Autonomous Vehicles at Intersections

We consider the coordination of autonomous vehicles at unsignalized intersections, where trajectory planning and crossing-order decisions are intrinsically coupled, thereby making their simultaneous optimization intractable in practice. To this end, we propose a heuristic based on a hierarchical structure consisting of a series of nonlinear programs (NLP) in the lower level, which optimizes trajectories of each vehicle for a given crossing order, and a high-level heuristic to design new crossing schedules that exploits sensitivity information from the lower-level NLPs. Extensive numerical simulations across a broad range of traffic scenarios demonstrate that our strategy achieves substantially improved scheduling with respect to first-in-first-out ordering while preserving computational tractability.

eess.SY↗