Search arXiv⌕ Search

arXiv · hep-ex/0412059

A Theory of Pattern Recognition for the Discrimination between Muon and Electron in the Super-Kamiokande

Abstract

The standard Super-Kamiokande analysis uses an estimator for particle identification by which it discriminates electrons (electron nutrinos) from muons (muon nutrinos). Use of this estimator has led to the claim of a significant deficiency of muons (muon nutrinos), suggesting the existence of neutrino oscillations. We investigate three areas of concern for the Super-Kamiokande estimator: the separation of the spatial part from the angular part in the probability functions, the neglect of fluctuations in the Cherenkov light in different physical processes due to the charged particles concerned, and the point-like approximation for the emission of Cherenkov light. We show that the first two factors are important for the consideration of stochastic processes in the generation of the Cherenkov light, and that the point-like assumption oversimplifies the estimation of the Cherenkov light quantities. We develop a new discrimination procedure for separating electron neutrinos from muon neutrinos, based on detailed simulations carried out with GEANT~3.21 and with newly derived mean angular distribution functions for the charged particles concerned (muons and electrons/positrons), as well as the corresponding functions for the relative fluctuations. These angular distribution functions are constructed introducing a ``moving point'' approximation. The application of our procedure between the discrimination between electron and muon to the analysis of the experimental data in SK will be made in a subsequent paper.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V. I. Galkin, A. M. Anokhina, E. Konishi, A. Misaki. 2007-03-29. A Theory of Pattern Recognition for the Discrimination between Muon and Electron in the Super-Kamiokande. https://arxiv.org/abs/hep-ex/0412059

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

First broadband search for fixed-polarization dark photon dark matter with GigaBREAD

We present the first search for fixed-polarization dark photon (DP) dark matter in the 44-52$μ\mathrm{eV}$ mass range, corresponding to 10.7-12.5GHz. GigaBREAD is a room-temperature broadband dish antenna experiment in which DP convert to ordinary photons on a cylindrical metallic emission surface and are focused onto a radio-frequency receiver. Previous searches, including GigaBREAD and several other dish antenna searches, have assumed randomly polarized DP dark matter. However, vector dark matter produced by a misalignment-like mechanism may retain an approximately fixed polarization, leading to sidereal modulation of the detector response as the Earth rotates. We reanalyze the GigaBREAD data using a polarization-matched likelihood that accounts for the time-dependent projection of a fixed DP polarization onto the detector axis. We find no evidence for a fixed-polarization DP signal and set upper limits on the kinetic mixing parameter at the level of $χ\sim10^{-12}$. These limits are about $20\%$ better than a naive limit obtained by rescaling the previous GigaBREAD limit under the fixed-polarization assumption.

hep-ex↗

Search for dark matter axions at 1-2 micro-eV with a RADES-DarkQuantum haloscope at CERN

The QCD axion remains one of the most compelling candidates for the dark matter of the Universe, yet the mass range around $1$\text{--}\SI{2}{\micro\electronvolt} remains essentially unexplored. In this paper, we describe a proposal to employ CERN's M1 superconducting magnet to deploy a haloscope to perform a search for galactic axion and axion-like particle dark matter providing continuous coverage from approximately 1.2 to 1.8 \SI{}{\micro\electronvolt}. Under conservative assumptions, the experiment can reach the QCD axion band over a significant fraction of the scanned range, while optimistic detector performance would allow sensitivity to benchmark models such as KSVZ and DFSZ over a large part of the explored mass interval. With the current long shut-down of CERN's accelerators providing a unique and timely window, such an experiment will deliver high-impact results even in conservative scenarios and potentially delivering a definitive test of the axion dark matter paradigm in the unexplored $1$\text{--}\SI{2}{\micro\electronvolt} mass range.

hep-ex↗

Data-quality monitoring of luminosity blocks with ATLAS Open Data: an open benchmark and a learned within-run detector

Data-quality monitoring at the LHC decides, luminosity block by luminosity block, which collision data enter physics analyses, yet its methods cannot be compared openly because the experiments' monitoring data are not public. We construct a public benchmark from the ATLAS Open Data release of the 2015--2016 proton--proton collisions at $\sqrt{s}=13$~TeV: 1289-bin histograms of reconstructed jets, electrons, photons, muons and the missing transverse momentum computed from them, for 39\,828 luminosity blocks of all 217 runs in the Good Run Lists; eight types of detector defects injected at event level at three strengths; real-data labels from the Good Run Lists and the liquid-argon calorimeter error flag; and a time-ordered protocol in which every detector is trained and calibrated on earlier runs only. Histogram shapes differ far more between runs than within a run (median $χ^2/n_\mathrm{dof}$ of 5.9 against 1.1), so references and autoencoders built across runs fail, and all competitive detectors use residuals with respect to a robust reference of each run. A gradient-boosted classifier on position-invariant features of these residuals, trained on synthetic defects and calibrated by split-conformal prediction, detects 43\% of the luminosity blocks with injected defects at a false-positive rate of 1.0\%, against 25\% for a matched-filter scan and 63\% for a single-histogram test that knows the defect pattern. For defect types excluded from its training, its efficiency falls to 18\%; adding pattern-agnostic synthetic detector failures to the training raises it to 34\%, above the scan, at a cost of three percentage points on the known types.

hep-ex↗